NX2A4E2 I
NTRODUCTION
NX2A4E2 User Manual
ADVANCED MICRO CONTROLS INC.
12
NX2A4E2 Programmable Parameters (continued)
Multi-turn Parameters (continued)
Linear Offset
The Linear Offset parameter changes the range of count values output by the unit and is used when the trans-
ducer position directly correlates to a linear measurement that does not start at zero. One such example is an
overhead crane. Another example is a press shut height measurement.
As an example of how the Linear offset works, when the Full Scale Count is set to 15,000 and the Linear Off-
set is set to zero, the NX2A4E2 will output position values from 0 to 14,999. If the Linear Offset is changed
to 10,000, then the unit will then output values from 10,000 to 24,999.
The default Linear Offset is zero.
For dual-resolver channels, the Linear Offset range is 0 to 999,999.
Preset Value
The transducer position can be set to any value within the range of Linear Offset to (Linear (Full
Scale Count – 1)). This parameter sets the value the transducer position is set to when the host controller
issues the Apply Preset command. This parameter has a factory default value of zero.
Front Panel Description
Figure R1.3 shows the front panel layout of the NX2A4E2 Resolver Interface. Note that the unit ships with
four Phoenix Contact connectors that are not shown for clarity. The RS485 channel, which is not imple-
mented at this time, does not ship with a connector
Figure R1.3 Front Panel Layout
Connector Pinout
Connector pinout and wiring is given in the appropriate section of the
chapter, start-
ing on page 31.
Section 1.4,
Section 1.5,
Section 1.8,
, which starts on page 37, begins the sections on transducer
wiring.
Section 1.10,
Additional sections of the installation chapter, such as
, must be reviewed and adhered to when actually installing the unit.
1 2
NEXUS
RESOLVER
POWER INPUT AND
CHASSIS GROUND
RESOLVER
STATUS LED's
DC INPUTS AND STATUS LED's
Brake Input Tied To Resolver 1.
Preset Input Not Presently Implemented.
RS485 COMM CHANNEL
For Future Expansion
Not Presently Implemented
MODULE
STATUS LED's
TRANSDUCER INPUT CONNECTORS
Each Connector Accepts (2) Single-Turn or
(1) Multi-turn Transducer.
ETHERNET RJ45 CONNECTOR
Port 1
ETHERNET RJ45 CONNECTOR
Port 2
DIP SWITCH BANK
Optionally sets IP Address
LINK2
PORT 2
PORT 1
MS
NS
LINK1
1
2
3
4
5
6
7
8
Содержание NEXUS NX2A4E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0N090 E2 Technology...
Страница 16: ...NX2A4E2 INTRODUCTION NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 16 Notes...
Страница 28: ...DATA FORMATS NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 28 Notes...
Страница 52: ...PROTOCOL SPECIFIC INFORMATION NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 52 Notes...
Страница 56: ...INSTALLING AN EDS FILE EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 66: ...ETHERNET IP EXPLICIT MESSAGING EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 66 Notes...
Страница 70: ...MODBUS TCP CONFIGURATION Modbus TCP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Страница 76: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...