1.7 Foreign Transducers
The NX2A4E2 is programmatically compatible with resolver transducers from Autotech and Gemco.
Resolver transducers from several other manufacturers can be made compatible with an AMCI Reference
Module. Each Reference Module is a single ended transformer that is wired into the transducer cable. The
Reference Module alters the reference voltage such that the return signals appear to come from an AMCI
transducer. Several different Reference Modules are available. Contact AMCI for additional information.
Regardless of the type of cable suggested by the transducer manufacturer, AMCI strongly rec-
ommends Belden 9730 or 9731, or exact equivalents, as cables for your transducer. With tens
of thousands of installations worldwide, AMCI is confident in the quality of these cables. If
you wish to use a different cable, contact AMCI to verify your cable type.
1.8 Transducer Connector Pinout
The transducer input connectors, labeled “
RESOLVER 1/2
” and “
RESOLVER 3/4
” have eight contacts. The
mating connectors are supplied with the NX2A4E2. The AMCI part number for the mating connector is
MS-8, while the Phoenix Contact part number is MSTB2.5/8-ST-5.08, order number 1757077. Figure T1.7
shows the connector pinout to industry standard wire designations. The single-turn pin out is shown on the
left and multi-turn pin out on the right.
Figure T1.7 Transducer Input Connector Pinout
Pin 3 is connected to the earth ground pin on the power connector. As covered in section 1.4,
on page 35, the earth ground pin on the power connector must be attached to the
system ground bus for proper operation.
8
7
6
5
4
3
2
1
BS3
BS4
AS3
AS4
AS1, AS2, BS1, BS2
All Shields
AR2, BR2
AR1, BR1
A – First Resolver Transducer
B – Second Resolver Transducer
R1/R2 – Reference Winding
S1/S3 – COS Winding
S2/S4 – SIN Winding
FS4
FS1
CS4
CS3
CS1, CS2, FS2, FS3
All Shields
CR2, FR2
CR1, FR1
F – Fine Resolver
C – Coarse Resolver
R1/R2 - Reference Winding
S2/S4 – SIN Winding
S1/S3 – COS Winding
Содержание NEXUS NX2A4E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0N090 E2 Technology...
Страница 16: ...NX2A4E2 INTRODUCTION NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 16 Notes...
Страница 28: ...DATA FORMATS NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 28 Notes...
Страница 52: ...PROTOCOL SPECIFIC INFORMATION NX2A4E2 User Manual ADVANCED MICRO CONTROLS INC 52 Notes...
Страница 56: ...INSTALLING AN EDS FILE EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 66: ...ETHERNET IP EXPLICIT MESSAGING EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 66 Notes...
Страница 70: ...MODBUS TCP CONFIGURATION Modbus TCP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Страница 76: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...