18
5
OPERATION
This section describes how the functionalities of the AMC-1BXX Gas Monitor are operated and
performed. Please consult the operation and initial configuration chapters below before attempting
to use or calibrate the Gas Monitor.
5.1 STATUS LEDS
Refer to Section 3.1 for LED location and descriptions.
During operation the LEDs will display the following configurations:
Table 5-1: Status LEDs
LED States
Network
Alarm Status Sensor Module Display Screen Message
Start Up
•
Initialization and
discovery of Sensor
Modules (after UTx
is powered up)
Off
Solid White
Solid White
AMC Splash Screen
•
Sensor Warm-up
Flashing Green
(.5 sec. cycle)
Solid White
Solid White
Main Info Screen
(or blank)
No sensor gas readings
shown
Network Status
No network connection
(assume all sensors
operational)
Flashing Green
(.5 sec. cycle)
Solid Green
Solid Green
Main Info Screen
(or blank)
Faults
•
At least one sensor
has gone under
range (more
–ve
than zero blanking
setting)
•
Bad sensor
configuration
•
Corrupted Sensor
Module Signal
•
Sensor Module
Missing
•
Incorrect Sensor
Module found
•
Sensor Module not
Communicating
Not Applicable
Solid Red
Solid Red
Not indicated on Display
Screen
•
Stuck
in
Bootloader
Solid Blue
Solid Blue
Solid Blue
Not indicated on Display
Screen
Содержание AMC-1BXX