WARN

IN

G

 

Do not use two (2) or more remote control systems  in the same area with the same dip switch 
settings,  as they will communicate with each other.  This may cause the appliances to 
malfunction.

 

 

 
 
Reset Button: 
 

1.

 

The reset button can be used  to reset the transmitter if  transmitter is not working properly.  The reset 
button (recessed) is located behind the battery door cover in the lower left corner of battery comparment. 
Using a paper clip, press the reset button and the transmitter will reset and initialize for 10 seconds before it 
can be used.

 

 
 

 
 

OPERATIONS 

 

 
Transmitter:

 

 

 
General: 
 

The RCSITEA Remote Control has two (2) operating modes: Manual and 
Thermostatic.  The control system can be set to temperature ranges between 45°F 
and 90°F.  The blower speed and flame height can be adjusted in either the manual 
and thermostatic mode. 
 
The transmitter will operate the remote receiver from 1foot to a maximum of 30 
feet. The distance is reduced when batteries are low or when the receiver is inside a 
metal enclosure. 

 
 
 
Initial Start-up: 
 

1.   After initial power up or when RESET button is pressed, the transmitter is reset. 

The reset button is located behind the battery door of transmitter. 

2.   During system reset, all features of the LCD DISPLAY will be visible. After 

one second, the LCD will be initialized. A typical reset display is shown above. 
Note that the temperature scale is degree F. 

3.   When only the "F" is displayed without the number, press On button to select 

between °C and °F display. It will exit setting mode automatically after 10 
seconds if no key is pressed.  The transmitter will send an Off signal after reset. 

4.   After reset, the transmitter is operating in manual mode. The room temperature 

is shown as above.  

 
 
 
 
 

Содержание RCSITEA

Страница 1: ...om you purchased the kit or Ambient Technologies Technical Support at 1 800 398 6195 Do not attempt to install any part of the kit unless all parts are in good condition Please keep this booklet for future reference Please check the gas type of the unit to match the current CONTENTS OF KIT Description Qty Transmitter 1 Battery Alkaline AAA for Transmitter 3 Receiver Assembly consists of 1 Receiver...

Страница 2: ...nty NOTE Due to the sensitive temperature monitoring components in the transmitter it is necessary to allow the transmitter to stabilize to room temperature before accurate room temperatures are displayed If the transmitter is activated from a severe cold condition allow 15 minutes for accurate temperature readings to appear on the LCD display WARNING Turn appliance OFF and allow to cool before in...

Страница 3: ...pliance Your appliance may have other options to connect wiring from receiver For applications longer than 22 inches use 18 gauge wire 105ºC rated with no splices Connect to the two 2 1 4 female spade wiring terminals and wire can be no longer than 20 feet WARNING Speed control module and thermal sensor must be removed before installing receiver and applying the AC power Failure to do so may cause...

Страница 4: ...TOP Make sure 120VAC fan and SIT valve are correct If not wired correctly this could cause damage to receiver Make sure that the wires do not contact the appliances any place other than at the terminals Exposure to temperatures higher than 105C 250ºF may cause the receiver to malfunction and cause possible fire hazard SIT mV Valve Hi Lo Regulator ...

Страница 5: ... DIP switches are preset at the factory In the event of activation or interference from other nearby transmissions reset the code using the following procedures 1 There are four switches on the transmitter and seven switches on the receiver see figure below Switches 1 2 3 and 4 on both transmitter and receiver are privacy switches and 5 6 7 on the receiver are blower switches 2 Slide the privacy c...

Страница 6: ... set to temperature ranges between 45 F and 90 F The blower speed and flame height can be adjusted in either the manual and thermostatic mode The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet The distance is reduced when batteries are low or when the receiver is inside a metal enclosure Initial Start up 1 After initial power up or when RESET button is pressed the ...

Страница 7: ...Press FAN button once to enter blower speed setup mode at low speed initially and one of the three blade icon will display darken on LCD display 2 Continue to press FAN button to set up the blower speed you desire 3 If there is no input within 3 seconds the new setting will be transmitted to receiver If fireplace is on the blower speed will take effect right away if fireplace is off the receiver w...

Страница 8: ...not operate with low batteries Change the batteries before the batteries are too weak for normal operation TURN THE UNIT OFF BEFORE REPLACING BATTERIES Child Proof Protection 1 Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter childproof mode as shown in this picture 2 The transmitter will not send a signal again until childproof mode is deactivated by pressing the ON and...

Страница 9: ...or location of the switches 2 In the event that the blower runs too slow or too fast on Low or Medium change the blower switch setting to achieve desired speed levels 3 Turn on the blower at Low speed with the transmitter and start from STEP 1 ON ON OFF then follow the following steps in the chart below to set up the blower switches The blower speed will decrease when going through the steps Stop ...

Страница 10: ... the main gas flame should extinguish but the pilot light will remain on 4 Slide the button to RS the center position then press the ON button on transmitter to turn the system ON The main gas flame should ignite and blower should come on after the On Delay Time is reached and fan speed you desire is selected 5 Press the OFF button on transmitter to turn the system to OFF The flame should extingui...

Страница 11: ...orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARRANTY This warranty gives you specific legal rights and you may also have other rights that vary from state to state or provin...

Страница 12: ...50D0111 RCSITEA Installation Operating Manual Rel 1 0 April 2009 Page 12 of 10 Ambient Technologies A Division Of Monessen Hearth Systems CALL 800 398 6195 ...

Отзывы: