background image

 

 

50D0111 

RCSITEA Installation & Operating Manual         

Rel 1.0  April 2009 

   Page 2 of 10 

                                     Ambient Technologies 

A Division Of  Monessen Hearth Systems

 

 

 

Quick Disconnect Wiring Assembly 

 

Reset Button for transmitter 

 

 
 

WARNING 

Important Safety Information

 

 
 

 

Read this manual thoroughly prior to installing, programming or operating any remote control. 

 

This remote control system is designed for use with a millivolt gas valve system with blower.  Do not use 
this remote control system on applications with voltages above 24 Volts AC/DC and 1 amp current. 

 

This remote control system requires three (3) “AAA” alkaline batteries to power the transmitter. The 
receiver is powered by external AC Adapter.   

 

Wiring must conform to appliance requirement and building codes/ordinances as required by local and 
national code authorities having jurisdiction. 

 

Do not short (or jumper) across the gas valve terminals to test the remote control installation. This could 
damage the unit and void the warranty. 

 

This remote control system should only be used as described in this manual.  Any other use is not 
recommended and will void the warranty. 

 
 

NOTE 

Due to the sensitive temperature monitoring components in the transmitter,  it is  necessary to 
allow the transmitter to stabilize to room temperature before accurate room temperatures are 
displayed.  If the transmitter is activated from a severe cold condition, allow 15 minutes for 
accurate temperature readings to appear on the LCD display. 

 

 

W

A

RNING 

Turn appliance OFF and allow to cool before installing or servicing.  DO NOT connect 
110-120 VAC wiring to the milli-volt gas control valve.  The remote operator must be installed 
exactly as outlined in these instructions.  Read all instructions completely before attempting 
installation.  Follow instructions carefully during installation.  Any modification of 
components will void the warranty and may cause a fire hazard.

 

 

W

A

RNING 

Turn appliance OFF (at the appliance or remote receiver) if you are away from your house for 
an extended period of time.  Never leave anything on top of the surface of the transmitter.   

 

 
 

INSTALLATIONS

 

 

Remote Receiver: 

 
The remote receiver may be installed in the appliance per the appliance homeowner’s manual. 

Refer to the 

Homeowner’s Manual for special installation instructions. 

  Failure to follow the installation instructions found 

in the appropriate Homeowner’s Manual will void the warranty and may cause a fire hazard. 
 

Содержание RCSITEA

Страница 1: ...om you purchased the kit or Ambient Technologies Technical Support at 1 800 398 6195 Do not attempt to install any part of the kit unless all parts are in good condition Please keep this booklet for future reference Please check the gas type of the unit to match the current CONTENTS OF KIT Description Qty Transmitter 1 Battery Alkaline AAA for Transmitter 3 Receiver Assembly consists of 1 Receiver...

Страница 2: ...nty NOTE Due to the sensitive temperature monitoring components in the transmitter it is necessary to allow the transmitter to stabilize to room temperature before accurate room temperatures are displayed If the transmitter is activated from a severe cold condition allow 15 minutes for accurate temperature readings to appear on the LCD display WARNING Turn appliance OFF and allow to cool before in...

Страница 3: ...pliance Your appliance may have other options to connect wiring from receiver For applications longer than 22 inches use 18 gauge wire 105ºC rated with no splices Connect to the two 2 1 4 female spade wiring terminals and wire can be no longer than 20 feet WARNING Speed control module and thermal sensor must be removed before installing receiver and applying the AC power Failure to do so may cause...

Страница 4: ...TOP Make sure 120VAC fan and SIT valve are correct If not wired correctly this could cause damage to receiver Make sure that the wires do not contact the appliances any place other than at the terminals Exposure to temperatures higher than 105C 250ºF may cause the receiver to malfunction and cause possible fire hazard SIT mV Valve Hi Lo Regulator ...

Страница 5: ... DIP switches are preset at the factory In the event of activation or interference from other nearby transmissions reset the code using the following procedures 1 There are four switches on the transmitter and seven switches on the receiver see figure below Switches 1 2 3 and 4 on both transmitter and receiver are privacy switches and 5 6 7 on the receiver are blower switches 2 Slide the privacy c...

Страница 6: ... set to temperature ranges between 45 F and 90 F The blower speed and flame height can be adjusted in either the manual and thermostatic mode The transmitter will operate the remote receiver from 1foot to a maximum of 30 feet The distance is reduced when batteries are low or when the receiver is inside a metal enclosure Initial Start up 1 After initial power up or when RESET button is pressed the ...

Страница 7: ...Press FAN button once to enter blower speed setup mode at low speed initially and one of the three blade icon will display darken on LCD display 2 Continue to press FAN button to set up the blower speed you desire 3 If there is no input within 3 seconds the new setting will be transmitted to receiver If fireplace is on the blower speed will take effect right away if fireplace is off the receiver w...

Страница 8: ...not operate with low batteries Change the batteries before the batteries are too weak for normal operation TURN THE UNIT OFF BEFORE REPLACING BATTERIES Child Proof Protection 1 Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter childproof mode as shown in this picture 2 The transmitter will not send a signal again until childproof mode is deactivated by pressing the ON and...

Страница 9: ...or location of the switches 2 In the event that the blower runs too slow or too fast on Low or Medium change the blower switch setting to achieve desired speed levels 3 Turn on the blower at Low speed with the transmitter and start from STEP 1 ON ON OFF then follow the following steps in the chart below to set up the blower switches The blower speed will decrease when going through the steps Stop ...

Страница 10: ... the main gas flame should extinguish but the pilot light will remain on 4 Slide the button to RS the center position then press the ON button on transmitter to turn the system ON The main gas flame should ignite and blower should come on after the On Delay Time is reached and fan speed you desire is selected 5 Press the OFF button on transmitter to turn the system to OFF The flame should extingui...

Страница 11: ...orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARRANTY This warranty gives you specific legal rights and you may also have other rights that vary from state to state or provin...

Страница 12: ...50D0111 RCSITEA Installation Operating Manual Rel 1 0 April 2009 Page 12 of 10 Ambient Technologies A Division Of Monessen Hearth Systems CALL 800 398 6195 ...

Отзывы: