*Alarm: ON (default)
Relay #6 closes on any of the following conditions:
1. Loss of a local area network connection
2. Loss of Internet connection to the uplink server
To turn the alarm off, use the following procedure.
1. Press [ENTER] to access the menu.
2. Press [ENTER] to edit the menu.
3. Press [DOWN] to get to the RECEIVER UTILITIES
4. Press [ENTER] to edit the utilities
5. Press [DOWN] to get to ALARM
6. Press [ENTER] to set it to OFF
7. Press [BACK] to save the changes
8. Press [BACK] until you are back to the main screen
*Clock Interval (Time sync relay) – default: OFF
This selects the minutes and seconds when relay #5 closes to
synchronize your clocks. This can be set to any minutes or
seconds you desire. The time sync used on the Wegener
Unity 4000® is at 54:30. The following procedure sets the
time sync relay on and the relay closure at 54:30. The
receiver comes shipped with this function off.
1. Press [ENTER] to access the menu
2. Press [ENTER] to edit the menu
3. Press [DOWN] to get to the CLOCK INTERVAL
4. Press [ENTER] to edit the settings
5. Press [ENTER] to turn the relay ON
6. Press [DOWN] to get to MINUTES:
7. Press [ENTER] to set it to 54
8. Press [DOWN] to get to SECONDS:
9. Press [ENTER] to set it to 30
10. Press [BACK] to save the changes
11. Press [BACK] until you are back to the main screen
The Time Sync relay closes for one second at the MM:SS setting. With the example listed
above, relay #5 would close every hour at XX:54:30 and open at XX:54:31.
*Closure Map
This allows you to change the relay assignments. The
section lists the different
functions and states. The names are listed in the
illustration to the right. The numbers are the relay
numbers. All six relays can be used if the time sync
and the alarm functions are not used. If they are used,
however, only the first four relays are available. This
section assumes that the alarm (#6) and time sync
(#5) functions are used and only relays #1-#4 are
available. A full description of the relays is found in
the
section.
The Relay Test Menu is only accessible by holding
down the [UP] and [DOWN] at the same time while
in this menu.
Rev. 1 – Firmware version 2.03
30
©
2012
Relay Test Menu - hidden
Closure Map
P2RS
P2RE
B2RS
B2RE
…
P1LS
P1LE
B1LS
B1LE
Off
Minutes
Seconds
Clock Interval