would trigger or it would set your time. You must go back to the
area and change
that function from relay #5 to another available relay.
Closure Map definitions
The following table describes the default mapped relays.
Relay names and Default assignments:
Descriptions
Name
Relay # State – Off, Pulse, On (default listed)
Program Start, Port 1 Left:
P1LS
None
Off
Program End, Port 1 Left:
P1LE
1
Pulse
Break Start, Port 1 Left:
B1LS
None
OFF
Break End, Port 1 Left:
B1LE 2
Pulse
Program Start, Port 2 Left:
P2LS
None
Off
Program End, Port 2 Left:
P2LE
3
Pulse
Break Start, Port 2 Left:
B2LS
None
Off
Break End, Port 2 Left:
B2LE 4
Pulse
Program Start, Port 1 Right: P1RS
None
Off
Program End, Port 1 Right:
P1RE
None
Off
Break Start, Port 1 Right:
B1RS None
Off
Break End, Port 1 Right:
B1RE None
Off
Program Start, Port 2 Right: P2RS
None
Off
Program End, Port 2 Right:
P2RE
None
Off
Break Start, Port 2 Right:
B2RS None
Off
Break End, Port 2 Right:
B2RE None
Off
When assigning functions to specific relay closures, remember that the “Left” assignment
should be used for stereo programs. Thus, playing a program out (live or prerecorded) port 1
in stereo or out port 1 in mono on the left channel, use the “Left” assignment. When playing
a mono program out the right channel of a port, use the “Right” assignments.
The state of the relay determines what happens when a command is sent. When a program
sends a command to the relay, here is what happens with each state.
1. OFF: The relay maintains its current state. If it was closed, it will stay closed.
2. ON: The relay will close stay that way until a release command is sent. If it was
already closed, then it will stay closed.
3. PULSE: The relay will close for one second and then release. If the relay was closed,
it will open one second after receiving the command.
The intent of the relay mapping is to allow you to assign a relay to a specific port. For
example, if you want a relay #2 to close only at the end of programming material when
you’re getting live programs on port 1, then you would map P1LE to relay #2.
Setting the relay mapping is done in the front panel menu under the
section.
Internal Clock
The internal clock is incredibly accurate because it is set by the GPS time standard at the
server facility. It automatically adjusts for the new Daylight Saving Time rules that went into
effect in 2007, with Daylight Saving Time beginning on the second Sunday in March and
ending on the first Sunday in November. The local time zone can also be set.