General safety instructions
Cenius03-2TX BAG0112.13 07.21
27
2.16.5 Brake system
•
Only specialist workshops or recognised brake services can
carry out adjustment and repair work on the brake system.
•
Have the brake system thoroughly checked regularly.
•
If there are any malfunctions, stop the tractor immediately using
the brake system. Have the malfunction rectified immediately.
•
Before performing any work on the braking system, park the
machine safely and secure the machine against unintentional
lowering or rolling away (wheel chocks).
•
Be particularly careful when carrying out any welding, torch cut-
ting or drilling work in the area of the brake lines.
•
Always carry out a braking test after any adjusting or repair work
on the braking system.
Pneumatic braking system
•
Before coupling the machine, clean the sealing rings on the hose
couplings of the supply and brake line.
•
Only move off with the machine connected when the pressure
gauge on the tractor shows 5.0 bar.
•
Drain the air reservoir every day.
•
Before driving without the machine, lock the hose couplings on
the tractor.
•
Hang the hose couplings of the machine supply and brake lines
in the appropriate empty couplings.
•
When filling up or replacing the brake fluid, use the prescribed
fluid. When replacing the brake fluid, comply with the appropriate
regulations.
•
Do not make any changes to the specified settings on the brake
valves.
•
Replace the air reservoir if:
ο
the air reservoir can be moved in the tensioning belts
ο
the air reservoir is damaged
ο
the rating plate on the air reservoir is rusty, loose or miss-
ing.
Hydraulic brake system for export machines
•
Hydraulic brake systems are prohibited in Germany.
•
When filling up or replacing the brake fluid, use the prescribed
hydraulic fluids. When replacing the hydraulic fluids, comply with
the appropriate regulations.