PIX-25
19
Setting Custom Print (Symbol Printing) (
P62
)
1.
With the cover removed, press and hold the
PROGRAM
button to begin
programming mode and
P1 TIME
will appear.
2.
Press the
CHANGE
button to change the current programming mode until
the display shows
P6 customize
.
3.
Press the
ENTER
button once and the clock will display the submenu for
other settings starting with
P-61 code prog
.
4.
Press the
CHANGE
button once and the clock will
display
P62 SYMBOL PR
.
5.
Press the
ENTER
button once and the clock will show
the current symbol selected for digit 1.
6.
If desired, press the
CHANGE
button to change the desired symbol for
digit 1.
7.
Press the
ENTER
button once and the clock will show the symbol for digit
2.
8.
If desired, press the
CHANGE
button to select the desired value for 2.
9.
Press the
ENTER
button once and the clock will show the symbol for digit
3.
10.
If desired, press the
CHANGE
button to select the desired value for 3.
11.
Press the
ENTER
button once and the clock will show the symbol for
digit 4. This process can continue until the maxium printing length of
154 dots is reached.
12.
Press the
PROGRAM
button exit programming and return the clock
back to normal operation.
Note
– Pressing the
PROGRAM
button while performing custom
print line setup with symbol printing will end the custom print
submenu without altering the program.
: 866-487-4751