background image

18 

PIX-25 

5.

 

If desired, press the 

CHANGE

 button to change the print digit year 

setting to the desired value. Your choices are 4 digit or 2 digit. Default = 

2 digit yr. 

6.

 

Press the 

ENTER

 button once and the clock will show the print time or 

print count format setting. 

7.

 

If desired, press the 

CHANGE

 button to select the desired value. Your 

choices are 

TIME PRIN

 or 

COUNT PRI

8.

 

Press the 

ENTER

 button once and the clock will show the print Day/Date 

format setting.

 

 

9.

 

If desired, press the 

CHANGE

 button to select the desired value. Your 

choices are 

Day, Date, MNTH DATE, DATE MNTH, DAY DATE, DATE 

DAY, YR MN DATE, DATE YR MN, MN DAT YR,

 or 

JULLIAN

10.

 

Press the 

ENTER

 button once and the clock will show the print time 

format setting. 

11.

 

If desired, press the 

CHANGE

 button to select the desired value. Your 

choices are

 12 HR 10

TH

, 24HR 10

TH

, 12HR 20

TH

, 24HR 20

TH

, 12HR 

60

TH

, 24HR 60

TH

, 12H 100

TH

, 24H 100

TH

, 24 60 SEC, 

or 

NO TIME

 
The user can set the print minutes from any of the following options: 

 

1/10

th

 Minutes – The minutes will be printed in 1/10 format, which means 

6 minutes equal to 0.1 hour. 

 

1/20

th

 Minutes – The minutes will be printed in 1/20 format, which means 

3 minutes equal 0.05 hour. 

 

1/60

th

 Minutes – The minutes will be printed in 1/60 format (Default), 

which means 1 minute equals 0:01 hour. 

 

1/100

th

 Minutes – The minutes will be printed in 1/100 format, which 

means 36seconds equal 0.01 hour. 

12.

 

If desired, press the 

CHANGE

 button to select the desired value. 

13.

 

Press the 

ENTER

 button once and the clock will show the print symbol 

format setting = 

NO SYMBOL

14.

 

Press the 

ENTER

 button once and the clock will flash current desired 

custom the print settings. 

15.

 

Press the 

ENTER

 button again to accept the print style settings and 

return back to the 

P6 CUSTOMIZE

 menu. 

16.

 

Press the 

PROGRAM

 button exit programming and return the clock 

back to normal operation. 

 

 

    

: 866-487-4751

VISIT: WWW.TIMECLOCKEXPERTS.COM

Содержание PIX-25

Страница 1: ...PIX 25 1 PIX 25 Atomic Time Clock Installation and Operation Guide TO PLACE AN ORDER CALL 866 487 4751 OR VISIT WWW TIMECLOCKEXPERTS COM...

Страница 2: ...due to the clocks failure to properly receive the radio signal because of interference whatever may be the source of this interference are hereby expressly excluded The PIX 25 has the atomic clock rad...

Страница 3: ...at P 58 16 Customize 17 Code Program Custom Printing P61 17 Setting Custom Print Symbol Printing P62 19 Diagnostics 22 Main Board Version d1 22 LCD Test d2 22 Show Number Printed d3 23 Clear Memory d4...

Страница 4: ...e the unit on an uneven or tilted surface This may result in injuries due to the unit dropping or falling off Do not put a water filled container or a metal object on top of the unit If water is spill...

Страница 5: ...PIX 25 5 Cover Removal 866 487 4751 VISIT WWW TIMECLOCKEXPERTS COM...

Страница 6: ...oam spacer white located under the print head Figure Release the printer carriage 4 After removing the foam spacer with the cover off plug in the clock Note Should the clock not power up verify that t...

Страница 7: ...urrent time settings exit programming and return to the normal display or press the ENTER button to return to programming mode Note During programming the time should be set depending on the mode the...

Страница 8: ...hen this setting is set to DISABLED the clock s time will not change for Daylight Saving 1 With the cover removed press and hold the PROGRAM button to begin programming mode and P1 TIME will appear 2...

Страница 9: ...2 digit year month date 24hr 60th hr 15JAN27 14 25 Pr 3 2 digit year month date 24hr 100th hr 15JAN27 14 42 Pr 4 2 digit year month date 24hr 10th hr 15JAN27 14 4 Pr 5 2 digit year month date 24hr 60...

Страница 10: ...utton to change the current programming mode until the display shows P5 OTHER 3 Press the ENTER button once and the clock will flash the P 51 submenu for language setting the 2nd line will display LAN...

Страница 11: ...DIC DEC DEZ DIC DEZ 12 received RCVD RCBDO RECU EING RICEV RCBDO RCVD sent SENT ENVDO ENV AUSG SPED ENVDO SENT faxed FAXED FAX FAXE FAX FAX FAX FAXED void VOID ANLDO ANNUL LAGER ANNUL ANUL VOID paid P...

Страница 12: ...er detection If your PIX 25 is not printing make sure you are triggering the paper sensor which can be changed with this parameter 1 With the cover removed press and hold the PROGRAM button to begin p...

Страница 13: ...button to change the current programming mode so the display shows P 54 lead zero 5 Press the ENTER button once and the clock will start flashing the current LEADING ZERO setting OFF or ON The default...

Страница 14: ...light Saving beginning or ending dates may require updating the system set Daylight Saving calendar The default start date setting March 08 2015 at 2 00AM which is the second Sunday of March 2015 If t...

Страница 15: ...d go to the previous menu 11 Press the CHANGE button once to move to next menu for setting DST End Date Note In order for the Daylight Saving Time feature to function correctly both Begin and End date...

Страница 16: ...nge the current setting if desired 7 Press the ENTER button once and the month will start flashing Press the CHANGE button to change the current month value if desired 8 Press the ENTER button once an...

Страница 17: ...r removed press the PROGRAM button to begin programming mode and P1 TIME will appear 2 Press the CHANGE button to change the current programming mode until the display shows P6 customize See the follo...

Страница 18: ...TH 12HR 60TH 24HR 60TH 12H 100TH 24H 100TH 24 60 SEC or NO TIME The user can set the print minutes from any of the following options 1 10th Minutes The minutes will be printed in 1 10 format which mea...

Страница 19: ...hange the desired symbol for digit 1 7 Press the ENTER button once and the clock will show the symbol for digit 2 8 If desired press the CHANGE button to select the desired value for 2 9 Press the ENT...

Страница 20: ...Hr and 60th Hr 59 38 82 100MIN 12H 12 Hr and 100th Hr 59 38 82 10MIN 24HR 24 Hr and 10th Hr 35 23 03 20MIN 24HR Skip Not Applicable 45 29 61 60MIN 24HR 24 Hr and 60th Hr 45 29 61 100MIN 24H 24 Hr and...

Страница 21: ...0th hr 15 APR 13 1 45 R PM 2D YEAR SPACE MONTH SPACE DATE SPA CE 12HR60TH END 2digit Year Month Date 24hr 60th hr 15 APR 13 13 45 2D YEAR SPACE MONTH SPACE DATE SPA CE 24HR60TH END 4digit Year Month D...

Страница 22: ...o begin programming mode and P1 TIME will appear 2 Press the CHANGE button to change the current programming mode until the display shows P7 Diagnose 3 Press the ENTER button once to display d1 soft r...

Страница 23: ...oft rev sub menu 4 Press the CHANGE button until the clock will displays d3 num print see Figure example on right 5 Press the ENTER button once and the clock will display the total number of prints wi...

Страница 24: ...on display atomic sync Enter 12 to turn off display atomic sync Enter 13 to reset 6 digit count Enter 32 to clear memory Enter 98 to clear all parameters plus the total print number Note FAQ If the A...

Страница 25: ...ws d6 advance 5 Press the ENTER button once to enter the diagnostic mode The clock will prompt the user to enter a 2 digit code by first flashing the lefthand digit on the bottom line Change the first...

Страница 26: ...may result in jams or damage to the clock Note Amano recommends using the manual print method see Setting the Print Method for large paper and transparent media printing Carbon Paper The PIX 25 clock...

Страница 27: ...operly under the following conditions Inside a large building between tall buildings underground or in buildings without windows Close to overhead power lines TV stations and train cables Close to hom...

Страница 28: ...nd arrows Step 4 Turn the knob on the cartridge clockwise one turn to take up any slack in the ribbon see right hand Figure Step 5 Stamp a card to check the printing quality and confirm that you have...

Страница 29: ...ay The possible error messages are listed in the following table along with their probable causes and solutions Note An error message can be possibly cleared by pressing the Reset button The Reset but...

Страница 30: ...ror reoccurs check the wires and cables to verify all components are connected properly Er 03 Home Position Sensor Unlock cover and remove Press the Reset button to reset the printer carriage and the...

Страница 31: ...he clock has power from the AC power adapter the clock will have all functionality and the display will show the current time date weekday ink level atomic clock signal level etc Power Off Mode During...

Страница 32: ...M see Figure 24 Hour Format In the 24 hour time format alias military time the hours will be displayed up to 23 The time after 12 hours would be considered PM For example 17 25 see Figure 5 25 PM 12 0...

Страница 33: ...PIX 25 33 Figure PIX 25 Clock Bottom Figure PIX 25 Clock Back Removed for Wall Mounting 866 487 4751 VISIT WWW TIMECLOCKEXPERTS COM...

Страница 34: ...etect paper for printing P 54 LEADING ZERO Enable disable leading zero from being printed P 56 DST BEGIN DATE Change DLS start date from factory default setting P 57 DST END DATE Change DLS end date f...

Страница 35: ...ng data and or clear custom data Warranty Notice Any claim for warranty expressed or implied due to the clock s failure to properly receive the radio signal because of interference whatever the source...

Страница 36: ...PIX 25 rear mounting plate level on the wall using 10 wood screws not included or equivalent 3 Verify that the cable for the AC Power Adapter is plugged into the back of the PIX 25 before hanging it...

Страница 37: ...PIX 25 37 Operation PIX 25 Views Figure Display View Figure 1 Internal View 866 487 4751 VISIT WWW TIMECLOCKEXPERTS COM...

Страница 38: ...and ink capacity Need Ribbons Keys and Accessories Visit The Atomic Time Synchronization Indicator in the LCD Display indicates the status of the signal When you first receive the clock it may be nece...

Страница 39: ...rmined by Amano Cincinnati Inc that the product has failed due to defects in materials and workmanship If the failure is for any other reason Amano Cincinnati Inc shall repair or replace the returned...

Страница 40: ...ears Ambient Temperature 10 C to 45 C 14 F to 113 F Ambient Humidity 10 to 90 non condensing Clock Accuracy 3 seconds week on AC Power 10 seconds week on Lithium Dimensions 6 11 16 170 mm Wide X 6 7 1...

Страница 41: ...ct for Product Notifications We contact our customers in case of product updates Owner Verification Registration can serve as verification of your ownership in the event of product theft or loss Effic...