Amano AXP-100 Operations Manual
5-13
No Keypress Timeout
The No Keypress Timeout means the time that the system allows for a key
on the keypad of the DEU to be pressed after a valid tag has been presented
to the DEU.
If it takes longer than the allowed time for a key to be pressed, the system
will reset and be ready for the presentation of the next tag.
To set the No keypress timeout, click on the
No keypress timeout
block in
the “Timeout” box. The figures in the block will be highlighted. Now, using the
number keys on the keyboard of the PC, type in the required figures between
0 and 255 (seconds). The new number will be displayed in the block.
Key Entry Time
The key entry time is the time that the system allows for a set of numbers
e.g. a reason code or a PIN, to be entered into the keypad of the DEU once
the first number has been typed or a tag presented and waits for PIN or
reason.
To set the no key entry time, click on the
Key entry time
block in the
Timeout
box. The figures in the block will be highlighted. Now, using the
number keys on the keyboard of the PC, type in the required figures between
3 and 60 seconds. The new number will be displayed in the block.
Long Keypress Time
To enter certain functions in the system, hold down the key allocated to that
specific function e.g. # for programming mode. The long keypress time is the
time set in the system for a key to be pressed before special functions can be
entered.
To set the long keypress time, use the mouse to click on the
Long keypress
time
block in the
Timeout
box. The figures in the block will be highlighted.
Now, using the number keys on the keyboard of the PC, type in the required
figures between 20 and 100. (100=10 seconds). The new number will be
displayed in the block.
Power Failure Timeout
If there is an AC power failure, the system will raise an alarm if the power is
not switched on again within a certain period of time. This period of time is
called the Power failure timeout.
To set the Power failure timeout, use the mouse to click on the
Power failure
timeout
block in the “Timeout” box. The figures in the block will be
highlighted. Now, using the number keys on the keyboard of the PC, type in
the required figures between 0 and 60 minutes (0 disables this feature). The
new number will be displayed in the block.
Содержание AXP-100
Страница 1: ...AMANO AXP 100 Single Door Access Control System System 101 Operations Manual Software V3 0...
Страница 6: ...iv Amano AXP 100 Operations Manual...
Страница 26: ...4 8 Amano AXP 100 Operations Manual...
Страница 70: ...5 44 Amano AXP 100 Operations Manual...
Страница 76: ...6 6 Amano AXP 100 Operations Manual Typical Card Template Typical Credit Card Tag Data...
Страница 80: ...6 10 Amano AXP 100 Operations Manual...
Страница 82: ...A 2 Amano AXP 100 Operations Manual...
Страница 87: ...Amano AXP 100 Operations Manual B 5 12 Select Other Devices...
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ...AAC 100401 IXP 313 0 0 GB 05 Copyright 2004 05 04 0...