COOLING PERFORMANCE DA
T
A
74 Rev. 3
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: RCB/VCB36A2B / CCA36F*C
Outdoor Ambient Temperature
65
75
85
95
105
115
Entering Indoor Wet Bulb Temperature
IDB*
Airflow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
MBh
34.3
35.6
39.0
-
33.5
34.7
38.1
-
32.7
33.9
37.1
-
31.9
33.1
36.2
-
30.3
31.4
34.4
-
28.1
29.1
31.9
-
S/T
0.72
0.60
0.42
-
0.75
0.63
0.43
-
0.77
0.64
0.44
-
0.79
0.66
0.46
-
0.82
0.69
0.48
-
0.83
0.69
0.48
-
Delta T
17
15
11
-
17
15
11
-
17
15
11
-
17
15
11
-
17
15
11
-
16
14
10
-
1350
KW
2.37
2.43
2.52
-
2.58
2.65
2.75
-
2.77
2.84
2.95
-
2.94
3.02
3.13
-
3.08
3.16
3.28
-
3.21
3.29
3.41
-
AMPS
9.7
10.0
10.3
-
10.6
10.8
11.2
-
11.5
11.8
12.2
-
12.3
12.7
13.1
-
13.2
13.5
14.0
-
14.0
14.3
14.8
-
HI PR
159
171
181
-
178
192
203
-
203
218
231
-
231
249
263
-
260
280
295
-
287
309
326
-
LO PR
62
66
72
-
65
70
76
-
68
72
79
-
71
76
83
-
75
80
87
-
77
82
90
-
MBh
33.3
34.5
37.8
-
32.5
33.7
36.9
-
31.8
32.9
36.1
-
31.0
32.1
35.2
-
29.4
30.5
33.4
-
27.3
28.3
31.0
-
S/T
0.69
0.58
0.40
-
0.71
0.60
0.41
-
0.73
0.61
0.42
-
0.76
0.63
0.44
-
0.79
0.66
0.45
-
0.79
0.66
0.46
-
Delta T
18
15
12
-
18
15
12
-
18
15
12
-
18
16
12
-
18
15
12
-
17
14
11
-
70
1200
KW
2.35
2.41
2.49
-
2.56
2.62
2.72
-
2.75
2.82
2.92
-
2.91
2.99
3.10
-
3.05
3.13
3.25
-
3.18
3.26
3.38
-
AMPS
9.6
9.9
10.2
-
10.5
10.7
11.1
-
11.4
11.7
12.1
-
12.2
12.5
13.0
-
13.0
13.4
13.8
-
13.8
14.2
14.7
-
HI PR
157
169
179
-
177
190
201
-
201
216
228
-
229
246
260
-
257
277
292
-
284
306
323
-
LO PR
61
65
71
-
65
69
75
-
67
72
78
-
71
75
82
-
74
79
86
-
77
81
89
-
MBh
30.7
31.9
34.9
-
30.0
31.1
34.1
-
29.3
30.4
33.3
-
28.6
29.6
32.5
-
27.2
28.2
30.9
-
25.2
26.1
28.6
-
S/T
0.67
0.56
0.38
-
0.69
0.58
0.40
-
0.71
0.59
0.41
-
0.73
0.61
0.42
-
0.76
0.63
0.44
-
0.76
0.64
0.44
-
Delta T
18
15
12
-
18
16
12
-
18
16
12
-
18
16
12
-
18
16
12
-
17
15
11
-
1050
KW
2.28
2.34
2.42
-
2.49
2.55
2.64
-
2.67
2.74
2.84
-
2.83
2.90
3.01
-
2.97
3.04
3.16
-
3.09
3.16
3.28
-
AMPS
9.4
9.6
9.9
-
10.2
10.4
10.8
-
11.1
11.4
11.7
-
11.9
12.2
12.6
-
12.7
13.0
13.4
-
13.4
13.8
14.3
-
HI PR
153
164
174
-
171
184
195
-
195
210
221
-
222
239
252
-
250
269
284
-
276
297
313
-
LO PR
59
63
69
-
63
67
73
-
65
69
76
-
69
73
80
-
72
76
83
-
74
79
86
-
MBh
34.9
35.9
38.9
41.7
34.1
35.1
38.0
40.8
33.3
34.3
37.1
39.8
32.5
33.4
36.2
38.8
30.8
31.7
34.4
36.9
28.6
29.4
31.8
34.2
S/T
0.82
0.74
0.56
0.36
0.85
0.76
0.58
0.37
0.87
0.78
0.59
0.38
0.90
0.81
0.61
0.39
0.94
0.84
0.63
0.41
0.94
0.84
0.64
0.41
Delta T
20
18
15
10
20
18
15
10
20
18
15
10
20
18
15
10
20
18
15
10
18
17
14
10
1350
KW
2.39
2.45
2.54
2.64
2.61
2.67
2.77
2.88
2.80
2.87
2.98
3.09
2.97
3.05
3.16
3.28
3.11
3.19
3.31
3.44
3.24
3.32
3.45
3.58
AMPS
9.8
10.1
10.4
10.8
10.7
10.9
11.3
11.7
11.6
11.9
12.3
12.8
12.5
12.8
13.2
13.7
13.3
13.6
14.1
14.7
14.1
14.5
15.0
15.6
HI PR
161
173
183
190
180
194
205
214
205
221
233
243
233
251
265
277
263
283
298
311
290
312
330
344
LO PR
62
66
73
77
66
70
77
82
69
73
80
85
72
77
84
89
76
80
88
93
78
83
91
97
MBh
33.9
34.9
37.7
40.5
33.1
34.1
36.9
39.6
32.3
33.3
36.0
38.6
31.5
32.4
35.1
37.7
29.9
30.8
33.4
35.8
27.7
28.5
30.9
33.2
S/T
0.78
0.70
0.53
0.34
0.81
0.73
0.55
0.35
0.83
0.75
0.56
0.36
0.86
0.77
0.58
0.37
0.89
0.80
0.60
0.39
0.90
0.81
0.61
0.39
Delta T
20
19
15
11
21
19
16
11
21
19
16
11
21
19
16
11
20
19
15
11
19
18
14
10
75
1200
KW
2.37
2.43
2.52
2.61
2.58
2.65
2.75
2.85
2.77
2.84
2.95
3.06
2.94
3.02
3.13
3.25
3.08
3.16
3.28
3.41
3.21
3.29
3.41
3.54
AMPS
9.7
10.0
10.3
10.7
10.6
10.8
11.2
11.6
11.5
11.8
12.2
12.7
12.3
12.7
13.1
13.6
13.2
13.5
14.0
14.5
14.0
14.3
14.8
15.4
HI PR
159
171
181
188
178
192
203
211
203
218
231
241
231
249
263
274
260
280
295
308
287
309
326
341
LO PR
62
66
72
77
65
70
76
81
68
72
79
84
71
76
83
88
75
80
87
92
77
82
90
96
MBh
31.3
32.2
34.8
37.4
30.5
31.4
34.0
36.5
29.8
30.7
33.2
35.7
29.1
29.9
32.4
34.8
27.6
28.4
30.8
33.0
25.6
26.4
28.5
30.6
S/T
0.76
0.68
0.51
0.33
0.78
0.70
0.53
0.34
0.80
0.72
0.54
0.35
0.83
0.74
0.56
0.36
0.86
0.77
0.58
0.37
0.87
0.78
0.59
0.38
Delta T
21
19
16
11
21
19
16
11
21
19
16
11
21
19
16
11
21
19
16
11
19
18
15
10
1050
KW
2.30
2.36
2.45
2.54
2.51
2.57
2.67
2.77
2.70
2.76
2.87
2.98
2.86
2.93
3.04
3.16
3.00
3.07
3.19
3.31
3.12
3.19
3.32
3.44
AMPS
9.5
9.7
10.0
10.4
10.3
10.5
10.9
11.3
11.2
11.5
11.9
12.3
12.0
12.3
12.7
13.2
12.8
13.1
13.6
14.1
13.6
13.9
14.4
15.0
HI PR
154
166
175
183
173
186
197
205
197
212
224
233
224
241
255
266
252
271
287
299
279
300
317
330
LO PR
60
64
70
74
63
67
74
78
66
70
77
81
69
74
80
86
73
77
84
90
75
80
87
93
* Entering Indoor Dry Bulb Temperature
NOTE: Shaded area is ACCA (TVA) conditions