40
Rev. 2
PRODUCT DESIGN
The following drawing illustrates a typical propane gas in-
stallation.
Typical Propane Gas Installation
WARNING
If your propane gas furnace is installed in a basement,
an excavated area or a confined space, we strongly
recommend that you contact your propane supplier
about installing a warning device that would alert you
to a gas leak.
. . . Propane gas is heavier than air and any leaking
gas can settle in any low areas or confined spaces.
. . . Propane gas odorant may fade, making the gas
undetectable except with a warning device.
An undetected gas leak would create a danger of ex-
plosion or fire. If you suspect the presence of gas, fol-
low the instructions below. Failure to do so could re-
sult in SERIOUS PERSONAL INJURY OR DEATH.
WARNING
If the information in these instructions is not followed
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
—Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other ap-
pliance.
—WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
—Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
PROPANE PIPING CHART
Pipe or
Tubing
Length,
Feet
10
730
1,700
3,200
5,300
8,300
3,200
7,500
20
500
1,100
2,200
3,700
5,800
2,200
4,200
30
400
920
2,000
2,900
4,700
1,800
4,000
40
370
850
1,700
2,700
4,100
1,600
3,700
50
330
770
1,500
2,400
3,700
1,500
3,400
60
300
700
1,300
2,200
3,300
1,300
3,100
80
260
610
1,200
1,900
2,900
1,200
2,600
100
220
540
1,000
1,700
2,600
1,000
2,300
125
200
490
900
1,400
2,300
900
2,100
150
190
430
830
1,300
2,100
830
1,900
175
170
400
780
1,200
1,900
770
1,700
200
160
380
730
1,100
1,800
720
1,500
To convert to capacities at 15 psig settings - multiply by 1.130
To convert to capacities at 5 psig settings - multiply by 0.879
Sizing Between First and Second Stage Regulator*
Maximum Propane Capacities listed are based on 2 psig pressure drop at 10 psig setting.
Capacities in 1,000 BTU/hour.
Tubing Size, O.D. Type L
Nominal Pipe Size
Schedule 40
3/8"
1/2"
5/8"
3/4"
7/8"
1/2"
3/4"
Maximum Propane Capacities Listed are Based on 1/2" W.C. pressure drop at 11" W.C. setting.
Capacities in 1,000 BTU/hour.
Pipe or
Tubing
Length,
Feet
10
39
92
199
329
501
935
275
567
1,071 2,205 3,307
20
26
62
131
216
346
630
189
393
732
1,496 2,299
30
21
50
107
181
277
500
152
315
590
1,212 1,858
40
19
41
90
145
233
427
129
267
504
1,039 1,559
50
18
37
79
131
198
376
114
237
448
913
1,417
60
16
35
72
121
187
340
103
217
409
834
1,275
80
13
29
62
104
155
289
89
185
346
724
1,066
100
11
26
55
90
138
255
78
162
307
630
976
125
10
24
48
81
122
224
69
146
275
567
866
150
9
21
43
72
109
202
63
132
252
511
787
200
8
19
39
66
100
187
54
112
209
439
665
250
8
17
36
60
93
172
48
100
185
390
590
*Data in accordance with NFPA pamphlet NO. 54
3/4"
1"
1-1/4" 1-1/2"
Sizing Between Single or Second Stage Regulator and Appliance*
Tubing Size, O.D. Type L
Nominal Pipe Size Schedule 40
3/8"
1/2"
5/8"
3/4"
7/8"
1-1/8"
1/2"
125K BTU/HR
(50CFH)
115
Gallon
115
Gallon
115
Gallon
250
Gallon
250
Gallon
400
Gallon
600
Gallon
250K BTU/HR
(100CFH)
250
Gallon
250
Gallon
250
Gallon
400
Gallon
500
Gallon
1000
Gallon
1500
Gallon
375K BTU/HR
(150CFH)
300
Gallon
400
Gallon
500
Gallon
500
Gallon
1000
Gallon
1500
Gallon
2500
Gallon
500K BTU/HR
(200CFH)
400
Gallon
500
Gallon
750
Gallon
1000
Gallon
1500
Gallon
2000
Gallon
3500
Gallon
750K BTU/HR
(300CFH)
750
Gallon
1000
Gallon
1500
Gallon
2000
Gallon
2500
Gallon
4000
Gallon
5000
Gallon
*Average rate/hour withdrawal in 8 hour period.
Maximum
Gas Needed
to Vaporize*
Tank Size required if lowest outdoor
temperature (Avg. for 24 Hours) reaches:
32°F
20°F
10°F
0°F
-10°F
-20°F
PROPANE TANK SIZING (MINIMUM)
-30°F