BLOWER PERFORMANCE SPECIFICATIONS
32
Rev. 2
TWO STAGE - VARIABLE SPEED
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "A". Installer should adjust blower speeds
as needed.
3. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE
RATING PLATE.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have
approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
Continuous Fan Speed Charts
Heating - Based Continuous Fan Speeds ("G" connected to "G" on Two-Stage Integrated Furnace Control)
Heating
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Heating
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
585
A
Minus
801
A
Normal
650
A
Normal
890
A
Plus
715
A
Plus
979
B
Minus
630
B
Minus
855
B
Normal
700
B
Normal
950
B
Plus
770
B
Plus
1045
C
Minus
720
C
Minus
945
C
Normal
800
C
Normal
1050
C
Plus
880
C
Plus
1155
D
Minus
810
D
Minus
1049
D
Normal
900
D
Normal
1165
D
Plus
990
D
Plus
1282
GUIV070DX40
GUIV090DX50
Heating
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Heating
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
945
A
Minus
945
A
Normal
1050
A
Normal
1050
A
Plus
1155
A
Plus
1155
B
Minus
990
B
Minus
990
B
Normal
1100
B
Normal
1100
B
Plus
1210
B
Plus
1210
C
Minus
1080
C
Minus
1080
C
Normal
1200
C
Normal
1200
C
Plus
1320
C
Plus
1320
D
Minus
1170
D
Minus
1170
D
Normal
1300
D
Normal
1300
D
Plus
1430
D
Plus
1430
GUIV140DX50
GUIV115DX50
Cooling - Based Continuous Fan Speeds ("G" connected to "G" on Interface Board)
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
405
A
Minus
540
A
Normal
450
A
Normal
600
A
Plus
495
A
Plus
660
B
Minus
540
B
Minus
742.5
B
Normal
600
B
Normal
825
B
Plus
660
B
Plus
907.5
C
Minus
743
C
Minus
945
C
Normal
825
C
Normal
1050
C
Plus
908
C
Plus
1155
D
Minus
945
D
Minus
1215
D
Normal
1050
D
Normal
1350
D
Plus
1155
D
Plus
1485
GUIV070DX40
GUIV90DX50
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
675
A
Minus
675
A
Normal
750
A
Normal
750
A
Plus
825
A
Plus
825
B
Minus
810
B
Minus
810
B
Normal
900
B
Normal
900
B
Plus
990
B
Plus
990
C
Minus
1080
C
Minus
1080
C
Normal
1200
C
Normal
1200
C
Plus
1320
C
Plus
1320
D
Minus
1350
D
Minus
1350
D
Normal
1500
D
Normal
1500
D
Plus
1650
D
Plus
1650
GUIV115DX50
GUIV140DX50