FURNACE SPECIFICATIONS
1. These furnaces are manufactured for natural gas operation. Optional LP Conversion Kits are available to convert to
propane gas.
2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not
be derated, orifice changes should only be made if necessary for altitude.
3. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method
of in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CON-
DITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating
capacity. Output based on D.O.E. test procedures, steady state efficiency times output.
4. Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
26
Rev. 2
* Off Heating - This fan delay timing is adjustable (60, 90, 120, 180 seconds). 90 seconds as shipped.
MODEL
GCIC045CX30
GCIC070CX30
GCIC070CX40
GCIC090CX30
GCIC090CX50
GCIC115CX40
GCIC115CX50
GCIC140CX50
Btuh Input (US)
46,000
69,000
69,000
92,000
92,000
115,000
115,000
140,000
Output (US)
36,800
55,200
55,200
73,600
73,600
92,000
92,000
110,400
A.F.U.E.
80%
80%
80%
80%
80%
80%
80%
80%
Rated External Static (WC)
.10 - .50
.12 - .50
.12 - .50
.15 - .50
.15 - .50
.20 - .50
.20 - .50
.20 - .50
Temperature Rise °F
35 - 65
45 - 75
45 - 75
45 - 75
45 - 75
45 - 75
45 - 75
45 - 75
Pressure Switch Trip Point
-0.55
-0.55
-0.55
-0.55
-0.55
-0.55
-0.55
-0.55
Blower Wheel (D x W)"
9 x 8
9 x 8
10 x 6
10 X 8
10 x 8
10 x 7
10 x 9
10 x 9
Blower Horsepower
1/3
1/3
1/2
1/3
1/2
1/2
3/4
3/4
Blower Speeds
4
4
4
4
4
4
4
4
Max CFM @ 0.5 E.S.P.
1160
1150
1370
1270
1780
1660
1840
1850
Power Supply
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
Min. Circuit Ampacity (MCA)
8.7
8.5
9.9
7.8
13.9
12.3
13.7
13.7
Max. Overcurrent Device
15
15
15
15
15
15
15
15
Transformer (VA)
40
40
40
40
40
40
40
40
Heat Anticipator
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
Limit Setting °F
240
200
170
170
160
130
130
140
Aux. Limit °F.
160
160
160
160
160
160
160
160
Fan Delay On
30 secs.
30 secs.
30 secs.
30 secs.
30 secs.
30 secs.
30 secs.
30 secs.
Off Heating *
90 secs.
90 secs.
90 secs.
90 secs.
90 secs.
90 secs.
90 secs.
90 secs.
Off Cooling
45 secs.
45 secs.
45 secs.
45 secs.
45 secs.
45 secs.
45 secs.
45 secs.
Gas Supply Pressure (Nat/LP)
7" / 11"
7" / 11"
7" / 11"
7" / 11"
7" / 11"
7" / 11"
7" / 11"
7" / 11"
Manifold Pressure (Nat/LP)
3.5 " / 10"
3.5 " / 10"
3.5 " / 10"
3.5 " / 10"
3.5 " / 10"
3.5 " / 10"
3.5 " / 10"
3.5 " / 10"
Orifice Size (Nat/LP)
#43 / #55
#43 / #55
#43 / #55
#43 / #55
#43 / #55
#43 / #55
#43 / #55
#43 / #55
Number of Burners
2
3
3
4
4
5
5
6
Vent Connector Diameter
3"
3"
3"
3"
3"
3"
3"
3"
Shipping Weight (lbs.)
140
151
152
169
178
190
194
198
Содержание GCIA045A30