SS-AMVC8
www.amana-hac.com
11
10
www.amana-hac.com
SS-AMVC8
p
roDuCT
S
peCiFiCATionS
p
roDuCT
S
peCiFiCATionS
w
iring
D
iAgrAM
Wiring
is
subject
to
change.
Al
wa
ys
refer
to
the
wiring
diag
ram
or
the
unit
for
the
most
up-to-da
te
wiring
.
⚠
W
arning
High
Voltage:
Disconnect
all
power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces
ma
y
be
pr
esent.
F
ailur
e
to
do
so
ma
y
cause
pr
operty
damage,
per
sonal
injur
y,
or
dea
th.
⚡
0140F00818
CC
SC
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
F
C
D
E
B
A
F
C
D
E
B
A
.125
SEE NOTE 3
9.175
.100
5.500
.100
THE GOODMAN MANUFACTURING COMPANY,L.P.
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
TITLE
LABEL, WIRING DIAGRAM
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED.
TOLERANCES:
ANGLES
1.5
.X
.1
.XX
.03
.XXX
.015
HOLES
: .005
DWN: RP
ENG: C. CANTRELL
SCALE: NTS
DATE: 5-14-10
CHK: SK
SHEET: 1
OF
1
DWG.
NO.
0140F00818
B
SPECIAL CHARACTERISTICS:
= 6SIGMA = CRITICAL CHARACTERISTIC = SIGNIFICANT CHARACTERISTIC
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF
GOODMAN MSP 824.01 WORKMANSHIP STANDARD FOR FIT, FEEL, AND FINISH.
CONFIDENTIAL PROPERTY OF THE GOODMAN FAMILY OF COMPANIES NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
ECN
REV
ZONE
DESCRIPTION
CHK DR
DATE
1004882
A
INITIAL RELEASE
SK RP
5-14-10
1005057
B
5.500 WAS 5.750, 9.175 WAS 9.750
SJK
7-20-10
NOTES:
1. MATERIAL: FLEXMARK PM 200 WHITE TC-245 L-23 SPEC 50K-8 WHITE POLYESTER FILM COATED
WITH A PERMANENT PRESSURE SENSITIVE ACRYLIC ADHESIVE AND BACKED WITH SEMI BLEACHED
KRAFT RELEASE LINER AS PER SPEC. S4900061, TYPE J
2. COLOR: BLACK PRINTING ON WHITE BACKGROUND.
3. REDUCE DIAGRAM TO DIMENSIONS SHOWN. FINAL PRINTED PART TO HAVE .125±.100
WHITE BORDER BEYOND THE PRINTED BORDER.
TO +VDC
TO
MICRO
TO
R
GND (4)
+ VDC (1)
RX (2)
TX (3)
CIRCULATOR
INDOOR
AIR
BLWR
RD
GY
BL
BK
PROPERLY POLARIZED
HUMIDIFIER
GND
PROTECTION DEVICE
HEAT OFF
DELAY
BURNER COMPARTMENT
24 V
3 A
BL
G
POWER SUPPLY WITH
LINE
RD
12
TO
C
2
BK
RD
UNUSED
DISCONNECT POWER
4
IGNITER
FLAME SENSOR
5 CIRCUIT CONNECTOR
INTEGRATED CONTROL MODULE
POWER BEFORE
BR
YL
TERMINAL
HI
BL
OR ORANGE
MVH (14)
4 CIRCUIT MOTOR
CONNECTOR
PM
ECM MTR
HARNESS
NO
24 VAC
HI VOLTAGE FIELD
115kBTU MODELS
AUTO RESET PRIMARY
LIMIT CONTROL
BEFORE SERVICING.
DIP SWITCHES
RD
PS1 (2)
3
YL YELLOW
CIRCULATOR
BK
BR BROWN
4
BK
OVERCURRENT
24V HUM.
0140F00818 REV. B
IGNITER
115 VAC/ 1
BLOWER COMPARTMENT
24
BK
PM
1
WH WHITE
B
K
FUSE
15
INDUCED
DRAFT
BLOWER
EAC
C
3
BL BLUE
6
115 VAC
INDUCTOR COIL
WH
YL
GND
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE
IN STANDBY (NO THERMOSTAT INPUTS)
Ø /60 HZ POWER SUPPLY WITH
ADJUST
TO 115VAC/ 1
BK BLACK
DEHUM
5
HEAT
LINE
INTEGRATED CONTROL MODULE
GND
24V HUM.
2
WH
HOT
SURFACE
IGNITER
MVC (8)
2
NEUTRAL
RD
DOOR
LOW FIRE PRESS.
SWITCH
4
3
2
CHASSIS GROUND
WH
VAC
GND
LOW VOLTAGE (24V)
2 CIRCUIT
CONNECTOR
HUM
DEHUM
2
HI VOLTAGE (115V)
OVERCURRENT
PSO (7)
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING.
ONLY
C
AIR CLEANER
TWO STAGE
GAS VALVE
(HONEY WELL)
DISCONNECT
HIGH FIRE
PRESS. SWTICH
INDOOR
HUMIDIFIER
Ø /60 HZ
PK PINK
N
W
H
9
MANUAL RESET ROLLOUT
LIMIT CONTROLS
IND LO
14
Y2
40 VA
AUTO RESET AUXILIARY LIMIT
CONTROLS
3
HUM
YL
JUNCTION
BLWR
PU PURPLE
1
CIRCULATOR
BLOWER
R
1
GND
JUNCTION BOX
SWITCH (TEMP.)
NEUTRAL
115kBTU MODELS
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
C
LINE
BK
YL
NEUTRAL
4
NEUTRAL
POLARIZED AND
11
C
FS
2
PLUG CONNECTION
EAC
DISCONNECT
PU
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
LEAST 105 C. USE COPPER CONDUCTORS ONLY.
TWO-STAGE
INTEGRATED
CONTROL
MODULE
RD
INTEGRATED CONTROL
PROT. DEVICE
8
HIGH FIRE
PRESSURE SWITCH
WH
ONLY
24 V THERMOSTAT CONNECTIONS
W1
W1
INTERNAL TO
70kBTU,90kBTU,
NO
EQUIPMENT GND
MVL (13)
O
SERVICING. WIRING
2ND STG DLY
WH
RD
YL
ID BLOWER TWO-STAGE PRESSURE
SWITCH ASSEMBLY
R
BL
2
5
GND (5)
BK
IND HI
IGN
PK
HLO (10)
70kBTU,90kBTU,
NOTES:
PU
L
AIR
Y1
WH
MANUAL RESET ROLLOUT LIMIT
CONTROLS
Y1
GY GRAY
ELECTRONIC
RD RED
Y2
RD
NEUTRAL
1
HLI (1)
WH
SWITCH
AUTO RESET PRIMARY
LIMIT CONTROL
NO
WH
TRANSFORMER
MUST BE PROPERLY
13
1
BL
OR
3
OVERCURRENT PROTECTION DEVICE
T-STAT
5
BR
BK
GN
2
GROUNDED.
LOW VOLTAGE FIELD
W2
DELAY
WARNING:
7
FIELD GND
FIELD SPLICE
SWITCH (PRESS.)
1
C
W2
WH
115
NEUTRAL
BLWR
JUNCTION BOX
3
GND
FS
1
AND GROUNDED.
4
B
K
GAS
VALVE
24V THERMOSTAT CONNECTIONS
PU
INDUCTOR COIL
TH (4)
C
HI
1
24V HUM.
TO UNIT MUST BE
VAC
G
YL
C
TR (11)
YL
GR
GN GREEN
HOT SURFACE
FLAME
SENSOR
PS2 (12)
LOW FIRE
PRESSURE
SWITCH
1
INTEGRATED CONTROL MODULE
COLOR CODES:
L
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO
N.E.C. AND LOCAL CODES.
YL
DIAGNOSTIC
LED'S
RD
O
3
DEHUM
10
WIRING TO UNIT
OR
NO
NEUTRAL
N
SEE
NOTE 5
BR
WH
COOL
40 VA
TRANSFORMER
ID
TO
MICRO
WARNING:DISCONNECT
PU
AUTO RESET
AUXILIARY
LIMIT CONTROL
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
FUSE 3 A
2
HEAT OFF
DELAY
24 V
3 A
BL
G
12
2
UNUSED
4
5 CIRCUIT CONNECTOR
4 CIRCUIT MOTOR
CONNECTOR
DIP SWITCHES
4
1
FUSE
15
6
ADJUST
5
HEAT
LINE
2
RD
DEHUM
2
9
14
Y2
3
HUM
1
YL
NEUTRAL
11
EAC
TWO-STAGE
INTEGRATED
CONTROL
MODULE
8
WH
24 V THERMOSTAT CONNECTIONS
W1
2ND STG DLY
RD
R
BL
2
Y1
13
1
3
T-STAT
5
BR
BK
DELAY
7
1
C
W2
3
FS
4
YL
YL
DIAGNOSTIC
LED'S
RD
O
DEHUM
10
OR
SEE
NOTE 5
COOL
GN
RD
BL
BK
B
B