background image

SS-AMVC8

 

www.amana-hac.com 

3

www.amana-hac.com 

SS-AMVC8

p

roDuCT

 S

peCiFiCATionS

p

roDuCT

 S

peCiFiCATionS

S

peCiFiCATionS

AMVC8 

0604B*B

AMVC8

0805C*B

AMVC8

1005C*B

ADVC8

0603B*B

ADVC8

0805C*B

ADVC8

1005C*B

Heating Capacity
High Fire Input (BTU/h)¹

60,000

80,000

100,000

60,000

80,000

100,000

High Fire Output (BTU/h)¹  (below)

     Natuarl Gas

48,000

64,000

80,000

48,000

64,000

80,000

     LP Gas

48,000

64,000

80,000

48,000

64,000

80,000

Low Fire Input (BTU/h)¹

42,000

56,000

70,000

42,000

56,000

70,000

Low Fire Output (BTU/h)¹  (below)

     Natuarl Gas

33,600

44,800

56,000

33,600

44,800

56,000

     LP Gas

33,600

44,800

56,000

33,600

44,800

56,000

AFUE2

80

80

80

80

80

80

Available AC @ 0.5” ESP

1.5 - 4.0

2.0 - 5.0

2.0 - 5.0

1.5 - 3.0

2.0 - 5.0

2.0 - 5.0

Temperature Rise Range (° F)

20 - 50

20 - 50

25 - 55

30-60

35 - 65

35-65

Circulator Blower
Size  (D x W)

10” x 8”

10” x 10”

10” x 10”

10” x 8”

10” x 10”

10” x 10”

Horsepower - RPM

¾

¾

¾

¾

¾

¾

Speed

Variable

Variable

Variable

Variable

Variable

Variable

Vent Diameter²

4”

4”

4”

4”

4”

4”

No. of Burners

3

4

5

3

4

5

Disposable Filter Size (in²)

610

813

1,016

474

569

711

Electrical Data
Min. Circuit Ampacity³

12.1

12.1

12.1

12.1

12.1

12.1

Max. Overcurrent Device (amps)⁴

15

15

15

15

15

15

Ship Weight (lbs)

152

178

194

155

177

193

1

  Natural Gas BTU/h; for altitudes above from 0’ to 4,500’ above sea level, reduce input rating 4% for each 1,000’ above 4,500’ altitude. Low-fire rate is 

75% of high-fire rate.

2

  DOE AFUE based upon Isolated Combustion System (ICS)

3

  Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical 

Codes. Extensive wire runs will require larger wire sizes.

4

  Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of 

the same size as noted.

Notes

•  All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•  Gas Service Connection ½” FPT
•  Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all  

existing local codes.

Содержание ADVC8 Series

Страница 1: ...Low NOx emissions compliant models available Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Designed for multi position installation upflow horizontal left...

Страница 2: ...H High Air ow K Dedicated Up ow Cabinet Width M Up ow Horizontal A 14 B 17 Descrip5on Motor C 21 V Two Stage Variable speed D 24 H Two Stage MulS speed S Single Stage MulS speed Maximum CFM 0 5 ESP E...

Страница 3: ...No of Burners 3 4 5 3 4 5 Disposable Filter Size in 610 813 1 016 474 569 711 Electrical Data Min Circuit Ampacity 12 1 12 1 12 1 12 1 12 1 12 1 Max Overcurrent Device amps 15 15 15 15 15 15 Ship Weig...

Страница 4: ...utlined in the Installation Manual for additional venting requirements Dimensions Model A B AMVC80604B 17 16 AMVC80805C 21 19 AMVC81005C 21 19 PRODUCT DIMENSIONS 8 AMVC8 GMVC8_____X Alt Gas Inlet High...

Страница 5: ...Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined in the Installation Manual for additional venting requirements Auto Comfort Mode During Auto Comfort mode the fu...

Страница 6: ...s 1 053 D Minus 1 053 Normal 910 Normal 1 170 Normal 1 170 Plus 1 001 Plus 1 287 Plus 1 287 1 to 8 W C ESP High or Single Stage Cooling Speeds AMVC80604B AMVC80805C AMVC81005C Cooling Speed Tap Adjust...

Страница 7: ...High Stage CFM Rise F A Minus 1090 1555 55 Normal 1210 1725 49 Plus 1330 1900 45 B Minus 1105 1575 54 Normal 1225 1750 49 Plus 1350 1925 44 C Minus 1120 1600 53 Normal 1245 1775 48 Plus 1370 1955 44 D...

Страница 8: ...Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM A Minus 351 A Minus 468 A Minus 497 Normal 390 Normal 520 Normal 553 Plus 429 Plus 572 Plus 608 B Min...

Страница 9: ...age CFM High Stage CFM Rise F A Minus 975 1395 61 Normal 1085 1550 55 Notes These charts are for furnaces installed at 0 4 500 At higher alti tudes a properly de rated unit will have the same temperat...

Страница 10: ...10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Страница 11: ...ROLS IND LO 40 VA AUTO RESET AUXILIARY LIMIT CONTROLS YL JUNCTION BLWR PU PURPLE CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR...

Страница 12: ...lity products may mean a change in specifications without notice 2012 Goodman Company L P Houston Texas Printed in the USA Accessories Model Description LPM 06 LP Conversion Kit Springs Orifice AFE18...