background image

SS-AMVC8

 

www.amana-hac.com 

3

www.amana-hac.com 

SS-AMVC8

p

roDuCT

 S

peCiFiCATionS

p

roDuCT

 S

peCiFiCATionS

n

oMenClATure

C

4

C

*

*

*

   

4

Brand

Revisions

A Amana

®

   Brand

Major   and
Minor   Revisions

Airflow   Direc5on

NOx

C

Downflow/Horizontal

N

Natural   Gas

D Dedicated   Downflow

X

Low   NOx

H High   Airflow

K

Dedicated   Upflow

Cabinet   Width

M Upflow/Horizontal

A         14”
B         17½”

Descrip5on/Motor

C         21”

V Two-­‐Stage/Variable-­‐speed

D         24½”

H Two-­‐Stage/MulS-­‐speed

S

Single-­‐Stage/MulS-­‐speed

Maximum   CFM   @   0.5”   ESP

E

Two-­‐Stage/High-­‐Efficiency

3         1200
4         1600

SystemType

5         2000

C

ComfortNet™   CommunicaSng   System

MBTU/h

AFUE

040:   40,000

100:   100,000

95 95%

8 80%

060:   60,000

120:   120,000

9

90%+

080:   80,000

13

060

6,7,8

8

M

2

10

11

12

1

A

V
3

5

9

Содержание ADVC8 Series

Страница 1: ...Low NOx emissions compliant models available Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Designed for multi position installation upflow horizontal left...

Страница 2: ...H High Air ow K Dedicated Up ow Cabinet Width M Up ow Horizontal A 14 B 17 Descrip5on Motor C 21 V Two Stage Variable speed D 24 H Two Stage MulS speed S Single Stage MulS speed Maximum CFM 0 5 ESP E...

Страница 3: ...No of Burners 3 4 5 3 4 5 Disposable Filter Size in 610 813 1 016 474 569 711 Electrical Data Min Circuit Ampacity 12 1 12 1 12 1 12 1 12 1 12 1 Max Overcurrent Device amps 15 15 15 15 15 15 Ship Weig...

Страница 4: ...utlined in the Installation Manual for additional venting requirements Dimensions Model A B AMVC80604B 17 16 AMVC80805C 21 19 AMVC81005C 21 19 PRODUCT DIMENSIONS 8 AMVC8 GMVC8_____X Alt Gas Inlet High...

Страница 5: ...Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined in the Installation Manual for additional venting requirements Auto Comfort Mode During Auto Comfort mode the fu...

Страница 6: ...s 1 053 D Minus 1 053 Normal 910 Normal 1 170 Normal 1 170 Plus 1 001 Plus 1 287 Plus 1 287 1 to 8 W C ESP High or Single Stage Cooling Speeds AMVC80604B AMVC80805C AMVC81005C Cooling Speed Tap Adjust...

Страница 7: ...High Stage CFM Rise F A Minus 1090 1555 55 Normal 1210 1725 49 Plus 1330 1900 45 B Minus 1105 1575 54 Normal 1225 1750 49 Plus 1350 1925 44 C Minus 1120 1600 53 Normal 1245 1775 48 Plus 1370 1955 44 D...

Страница 8: ...Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM A Minus 351 A Minus 468 A Minus 497 Normal 390 Normal 520 Normal 553 Plus 429 Plus 572 Plus 608 B Min...

Страница 9: ...age CFM High Stage CFM Rise F A Minus 975 1395 61 Normal 1085 1550 55 Notes These charts are for furnaces installed at 0 4 500 At higher alti tudes a properly de rated unit will have the same temperat...

Страница 10: ...10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Страница 11: ...ROLS IND LO 40 VA AUTO RESET AUXILIARY LIMIT CONTROLS YL JUNCTION BLWR PU PURPLE CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR...

Страница 12: ...lity products may mean a change in specifications without notice 2012 Goodman Company L P Houston Texas Printed in the USA Accessories Model Description LPM 06 LP Conversion Kit Springs Orifice AFE18...