background image

SS-AMVC8

 

www.amana-hac.com 

5

www.amana-hac.com 

SS-AMVC8

p

roDuCT

 S

peCiFiCATionS

p

roDuCT

 S

peCiFiCATionS

AMVC8  D

iMenSionS

M

iniMuM

 C

leArAnCeS

 

To

 C

oMbuSTible

 M

ATeriAlS

Sides

Rear

Front ¹

Vent ²

Top

SW

B

1

0

3

6

1

1

Approved for line contact in the horizontal position.
¹  24” clearance for serviceability recommended.
²  Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the  

Installation Manual for additional venting requirements.

D

iMenSionS

 Model

A

B

AMVC80604B**

17½”

16”

AMVC80805C**

21”

19½”

AMVC81005C**

21”

19½”

PRODUCT DIMENSIONS

8

AMVC8/GMVC8_____X*

Alt. Gas Inlet

High Voltage Inlet

Low Voltage

Alt. Gas Inlet

Alt. High Voltage

Alt. LowVoltage

MODELS

A

B

AMVC80704BX**

GMVC80704BX**

17-1/2

16

AMVC80905CX**

AMVC81155CX**

GMVC80905CX**

GMVC81155CX**

21

19-1/2

All dimensions are in inches.

1¾˝

1⁷

/

₁₆˝

23⁵

/

₁₆˝

33³

/

₈˝

27⁷

/

₈˝

20˝

13¼˝

23¾˝

28˝

High-Voltage Inlet

Low-Voltage Inlet

Alt. Gas Inlet

Alt. Gas Inlet

Alt. High Voltage

Alt. Low Voltage

19½˝

19½˝

Содержание ADVC8 Series

Страница 1: ...Low NOx emissions compliant models available Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Designed for multi position installation upflow horizontal left...

Страница 2: ...H High Air ow K Dedicated Up ow Cabinet Width M Up ow Horizontal A 14 B 17 Descrip5on Motor C 21 V Two Stage Variable speed D 24 H Two Stage MulS speed S Single Stage MulS speed Maximum CFM 0 5 ESP E...

Страница 3: ...No of Burners 3 4 5 3 4 5 Disposable Filter Size in 610 813 1 016 474 569 711 Electrical Data Min Circuit Ampacity 12 1 12 1 12 1 12 1 12 1 12 1 Max Overcurrent Device amps 15 15 15 15 15 15 Ship Weig...

Страница 4: ...utlined in the Installation Manual for additional venting requirements Dimensions Model A B AMVC80604B 17 16 AMVC80805C 21 19 AMVC81005C 21 19 PRODUCT DIMENSIONS 8 AMVC8 GMVC8_____X Alt Gas Inlet High...

Страница 5: ...Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined in the Installation Manual for additional venting requirements Auto Comfort Mode During Auto Comfort mode the fu...

Страница 6: ...s 1 053 D Minus 1 053 Normal 910 Normal 1 170 Normal 1 170 Plus 1 001 Plus 1 287 Plus 1 287 1 to 8 W C ESP High or Single Stage Cooling Speeds AMVC80604B AMVC80805C AMVC81005C Cooling Speed Tap Adjust...

Страница 7: ...High Stage CFM Rise F A Minus 1090 1555 55 Normal 1210 1725 49 Plus 1330 1900 45 B Minus 1105 1575 54 Normal 1225 1750 49 Plus 1350 1925 44 C Minus 1120 1600 53 Normal 1245 1775 48 Plus 1370 1955 44 D...

Страница 8: ...Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM A Minus 351 A Minus 468 A Minus 497 Normal 390 Normal 520 Normal 553 Plus 429 Plus 572 Plus 608 B Min...

Страница 9: ...age CFM High Stage CFM Rise F A Minus 975 1395 61 Normal 1085 1550 55 Notes These charts are for furnaces installed at 0 4 500 At higher alti tudes a properly de rated unit will have the same temperat...

Страница 10: ...10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Страница 11: ...ROLS IND LO 40 VA AUTO RESET AUXILIARY LIMIT CONTROLS YL JUNCTION BLWR PU PURPLE CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR...

Страница 12: ...lity products may mean a change in specifications without notice 2012 Goodman Company L P Houston Texas Printed in the USA Accessories Model Description LPM 06 LP Conversion Kit Springs Orifice AFE18...