Form No. PDS CK3B.24.2

 

Cased Horizontal
Furnace Coil

 

CK3B

 

Sizes A024 thru A060

 

This horizontal N-Coil is designed to provide the highest
standard of reliability and durability. The CK3B coil casing is
unpainted embossed galvanized steel. The cabinet is fully
insulated to minimize energy loss.

The CK3B is designed for application with horizontal furnaces.
The 2-directional airflow allows for either horizontal-right or
horizontal-left furnace fit-up. This coil is ideally suited for either
attic or crawl space installation.

Our advanced manufacturing methods give a better bond of the
fin and tube. Contaminants are not introduced into coil during
manufacturing. Galvanic action is minimized. The coils are
approved for air conditioning or heat pump application in the
horizontal configuration.

The CK3B coil includes a refrigerant control metering device for
improved serviceability over check valves and expansion
devices used in conventional coils. Sweat-type connections are
furnished for installation of the refrigerant tubes.

The coil is designed to provide improved condensate removal.
The robust condensate pan has brass inserts in the primary and
secondary drain connections and meets FHA requirements.

 

Содержание CK3B

Страница 1: ...l space installation Our advanced manufacturing methods give a better bond of the fin and tube Contaminants are not introduced into coil during manufacturing Galvanic action is minimized The coils are approved for air conditioning or heat pump application in the horizontal configuration The CK3B coil includes a refrigerant control metering device for improved serviceability over check valves and e...

Страница 2: ...on 042 3 1 2 Ton 048 4 Ton 060 5 Ton A Standard N Narrow W Wide X Max Cap Position A Painted B Embossed CERTIFICATION LISTING TESTING INSPECTION M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 240 U N I T A R Y HE A T P U M P EQUIPMENT M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 210 U N I T A R Y AIR CO N D I T I O N I N G...

Страница 3: ...17 9 16 22 1 16 10 1 4 3 4 16 45 5 CK3BXA042 21 1 16 22 1 16 10 1 4 7 8 19 1 2 47 0 CK3BXA048 21 1 16 22 1 16 10 1 4 7 8 19 1 2 51 0 CK3BXA060 24 9 16 28 1 8 13 3 6 7 8 23 64 0 C A D SUCTION LINE 9 1 8 4 3 8 3 3 8 IN LIQUID LINE 3 4 IN NPT DRAIN B 1 11 16 20 3 4 3 15 16 1 1 2 3 8 E OPTIONAL DUCT FILLER PANEL 18 7 8 2 7 8 1 1 4 FRONT RIGHT SIDE DUCT OPENING TYPICAL BOTH ENDS ...

Страница 4: ... 09 58 5 28 5 0 06 48 4 24 8 0 06 67 69 4 42 5 0 06 61 3 38 9 0 06 53 1 35 4 0 05 44 4 31 7 0 05 34 5 27 5 0 07 62 56 6 46 2 0 04 49 3 42 5 0 06 42 0 38 8 0 07 34 3 34 3 0 11 28 8 28 8 0 25 A042 1050 72 75 4 35 0 0 00 68 0 31 8 0 00 60 7 28 6 0 02 52 7 25 3 0 00 43 6 21 7 0 00 67 62 1 37 3 0 00 55 0 34 0 0 00 47 8 30 7 0 00 39 3 26 9 0 01 30 2 23 1 0 03 62 51 5 39 8 0 01 44 2 36 2 0 01 36 9 32 7 0...

Страница 5: ...of next lower EWB for approximation Interpolation is permissible Correction Factor 1 09 x 1 BF x db 80 sensible heat cap 1 09 x CFM total capacity Btuh 4 5 x CFM BYPASS FACTOR ENTERING AIR DRY BULB TEMPERATURE F 79 78 77 76 75 Under 75 81 82 83 84 84 Over 85 Correction Factor 0 10 0 98 1 96 2 94 3 92 4 91 Use formula shown below 0 20 0 87 1 74 2 62 3 49 4 36 0 30 0 76 1 53 2 29 3 05 3 82 COIL STAT...

Страница 6: ... 6 TYPICAL N COIL HORIZONTAL INSTALLATIONS Horizontal Left FILLER PLATE N COIL AIRFLOW FURNACE DRAIN CONNECTION A97203 FILLER PLATE N COIL AIRFLOW FURNACE DRAIN CONNECTION Horizontal Right A97037 ...

Страница 7: ... 7 ...

Страница 8: ...n this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays dividends in faster ...

Отзывы: