background image

 

—6—

 

TYPICAL N-COIL HORIZONTAL INSTALLATIONS

Horizontal Left

FILLER PLATE

N-COIL

AIRFLOW

FURNACE

DRAIN
CONNECTION

A97203

FILLER PLATE

N-COIL

AIRFLOW

FURNACE

DRAIN
CONNECTION

Horizontal Right

A97037

Содержание CK3B

Страница 1: ...l space installation Our advanced manufacturing methods give a better bond of the fin and tube Contaminants are not introduced into coil during manufacturing Galvanic action is minimized The coils are approved for air conditioning or heat pump application in the horizontal configuration The CK3B coil includes a refrigerant control metering device for improved serviceability over check valves and e...

Страница 2: ...on 042 3 1 2 Ton 048 4 Ton 060 5 Ton A Standard N Narrow W Wide X Max Cap Position A Painted B Embossed CERTIFICATION LISTING TESTING INSPECTION M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 240 U N I T A R Y HE A T P U M P EQUIPMENT M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I T H A RI STANDARD 210 U N I T A R Y AIR CO N D I T I O N I N G...

Страница 3: ...17 9 16 22 1 16 10 1 4 3 4 16 45 5 CK3BXA042 21 1 16 22 1 16 10 1 4 7 8 19 1 2 47 0 CK3BXA048 21 1 16 22 1 16 10 1 4 7 8 19 1 2 51 0 CK3BXA060 24 9 16 28 1 8 13 3 6 7 8 23 64 0 C A D SUCTION LINE 9 1 8 4 3 8 3 3 8 IN LIQUID LINE 3 4 IN NPT DRAIN B 1 11 16 20 3 4 3 15 16 1 1 2 3 8 E OPTIONAL DUCT FILLER PANEL 18 7 8 2 7 8 1 1 4 FRONT RIGHT SIDE DUCT OPENING TYPICAL BOTH ENDS ...

Страница 4: ... 09 58 5 28 5 0 06 48 4 24 8 0 06 67 69 4 42 5 0 06 61 3 38 9 0 06 53 1 35 4 0 05 44 4 31 7 0 05 34 5 27 5 0 07 62 56 6 46 2 0 04 49 3 42 5 0 06 42 0 38 8 0 07 34 3 34 3 0 11 28 8 28 8 0 25 A042 1050 72 75 4 35 0 0 00 68 0 31 8 0 00 60 7 28 6 0 02 52 7 25 3 0 00 43 6 21 7 0 00 67 62 1 37 3 0 00 55 0 34 0 0 00 47 8 30 7 0 00 39 3 26 9 0 01 30 2 23 1 0 03 62 51 5 39 8 0 01 44 2 36 2 0 01 36 9 32 7 0...

Страница 5: ...of next lower EWB for approximation Interpolation is permissible Correction Factor 1 09 x 1 BF x db 80 sensible heat cap 1 09 x CFM total capacity Btuh 4 5 x CFM BYPASS FACTOR ENTERING AIR DRY BULB TEMPERATURE F 79 78 77 76 75 Under 75 81 82 83 84 84 Over 85 Correction Factor 0 10 0 98 1 96 2 94 3 92 4 91 Use formula shown below 0 20 0 87 1 74 2 62 3 49 4 36 0 30 0 76 1 53 2 29 3 05 3 82 COIL STAT...

Страница 6: ... 6 TYPICAL N COIL HORIZONTAL INSTALLATIONS Horizontal Left FILLER PLATE N COIL AIRFLOW FURNACE DRAIN CONNECTION A97203 FILLER PLATE N COIL AIRFLOW FURNACE DRAIN CONNECTION Horizontal Right A97037 ...

Страница 7: ... 7 ...

Страница 8: ...n this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays dividends in faster ...

Отзывы: