PRODUCT IDENTIFICATION
11
MODEL #
MFG #
DESCRIPTION
AFE18-60A
N/A
Fossil Fuel Kit.
The AFE18-60A control is designed for use where the indoor coil is
located above/downstream of a gas or fossil fuel furnace when used with a heat pump.
It will operate with single and two stage heat pum ps and single and two stage
furnaces. The AFE18-60A control will turn the heat pump unit off when the furnace is
turned on. An anti-short cycle feature initiates a 3 minute tim ed off delay when the
compressor goes off.
AMU1620
AMU1625
AMU2020
AMU2025
P1251305F
P1251306F
P1251307F
P1251308F
GMU1620
GMU1625
GMU2020
GMU2025
N/A
ASAS-10
ASAS-11
ASAS-12
ASAS-18
P1251301F
P1251302F
P1251303F
P1251304F
Electronic Air Cleaner.
The High-Efficiency Electronic Air Cleaner is designed to
remove air contam inants down to .01 microns. Carbon filters (optional) rem ove odors.
Dual indicator lights show unit operation at a glance. Electronic proving switch cycles
the air cleaner On/Off with the system fan. Durable powder-coat paint finish resists
corrosion.
CFSB17
CFSB21
CFSB24
N/A
Counterflow Subbase Kit
. For use with 34.5" down flow furnace m odels
.
These kits
are available for the following furnace widths: 17.5" wide (CFSB17), 21" wide (CFSB21)
and 24.5" wide (CFSB24). The kits m ust be used to prevent excessive temperature
from reaching com bustible m aterials, if the furnace is installed on a combustible floor.
This subbase effectively separated the furnace base and plenum from com bustible
m aterials. To ensure safe installation, do not install the counterflow floor base directly
on carpeting, tile, or other combustible material other than wood flooring.
Media Air Cleaner.
A high efficiency air filtration device designed to remove dirt, dust,
pollen and other m icroscopic particles from the air passing through it. Flexible
perform ance range up to 2,000 CFM capacity. The air cleaner should be installed in the
system so that all the system air is circulated through the air cleaner. The air cleaner
will only rem ove the airborne contaminants delivered to it. Maxim um performance is
obtained when the system blower is set for continuous operation. Carbon filters
(optional) are available.