background image

3-90-70744R11_05/13

R1

SAFETY NOTICE

PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR HEATING APPLIANCE.  FAILURE 
TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

FOR USE IN THE U.S. AND CANADA.  NOT SUITABLE FOR INSTALLATION IN MOBILE HOMES

IF THIS FURNACE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.  FOR YOUR SAFETY, FOLLOW 
INSTALLATION DIRECTIONS.  

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION 
REQUIREMENTS IN YOUR AREA.

CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE 
PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.

THIS APPLIANCE IS ALSO APPROVED FOR INSTALLATION INTO A SHOP.

SAVE THESE INSTRUCTIONS.

 SF1500A, SF2500A, SF2600A, SF3500A

Hot Air Furnaces

Installation & Operating Manual

“Ce manuel est disponible en Français sur demande”

Содержание SF1500A

Страница 1: ...IRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA CONTACT YOUR LOCAL AUTHO...

Страница 2: ...g 13 Maintenance 14 6SHFL FDWLRQV Coil Installation 16 Oil Burner Setup 18 Service Parts 19 Warranty 27 Contains updated information Harman Central Heating Appliances are built and tested to be comple...

Страница 3: ...unction Boxes Relay High Limit Snap Disc 4 1 4 X 3 4 bolts 4 Filter Box Mounting Clips 36 Flex Conduit 1 Straight Conduit Fitting 1 Elbow Conduit Fitting Ash Pan Shaker Handle Owner s Manual Warranty...

Страница 4: ...an Switch not on SF3500 Thermostat Junction Box Relay 4 1 4 X 3 4 bolts 4 Filter Box Mounting Clips 36 Flex Conduit 1 Straight Conduit Fitting 1 Elbow Conduit Fitting Ash Pan Shaker Handle Owner s Man...

Страница 5: ...es above the plenum Locatethefurnaceasclosetothechimneyaspossiblewhilestillmaintaining the abo e clearances o more than feet of sto epipe should be used including two or less 90 elbows All hori ontal...

Страница 6: ...nit from it s box Loosen the four bolts in the pipe on the front of the furnace Insert the nose of the oil gun into the pipe Before sliding the oil burner all the way in apply the gasket around the no...

Страница 7: ...d blower EHIRUH WKH OWHU ER All hardware brackets etc for the blower will be found in the carton with the blower 1H W SRVLWLRQ WKH EORZHU LQ WKH OWHU ER FHQWHUHG behind the inlet hole and allow approx...

Страница 8: ...high limit switch is packaged with a umper between the two sets of terminals inside REMO E THE J MPER WIRE I SIDE THE FA CO TROL The fan control should be installed in the right side of the plenum and...

Страница 9: ...9 3 90 70744R11_05 13 SF3500 Wiring Diagram...

Страница 10: ...10 3 90 70744R11_05 13 SF2600 Wiring Diagram...

Страница 11: ...t is the high limit ad ustment 3UH VHW DW GHJUHHV LW V IXQFWLRQ LV WR FORVH WKH DXWRPDWLF GUDIW FRQWURO DSSHU GRRU LI WKH temperature in the plenum reaches 200 degrees Do not change this setting The c...

Страница 12: ...r using the same method as before always closing the bottom door before opening the top door 1RZ ORDG WKH UHER ZLWK ZRRG WR WKH GHVLUHG IXOOQHVV OO Harman furnaces may be loaded with wood as full as p...

Страница 13: ...from the door Whene er the bottom door is open it should be closed before opening the loading door This is to increase draft through the loading door and pre ent excess smoke from escaping 7KH UHER VK...

Страница 14: ...f a brick is broken and has fallen out of place it should be replaced immediately 7KH UHEULFN XVHG LQ WKH DUPDQ IXUQDFHV DUH LQH SHQVLYH and easy to replace The blower manufacturer recommends the blow...

Страница 15: ...l Optional Firebox Dimensions Inches 16Wx22Lx20 5H 1 Wx26Lx21 5H 1 Wx26Lx21 5H 1 Wx30Lx25H Recommended Log Length 1 in 22 in 22 in 27 in Maximum Log Length 22 in 26 in 26 in 30 in Flue Size 6 in 7 in...

Страница 16: ...ele ated if necessary to allow for proper thermo siphon action The method by which hot water will circulate automatically through the system A Shut off the water heater and the water supply to it Dra...

Страница 17: ...n the tank completely B Remo e the Temp Presure relief al e and discard Install a short 3 4 in nipple and tee 1 along with a new relief al e C Remo e the drain al e at the bottom of the tank Install a...

Страница 18: ...ion Air C o 1 to 1 Draft Inches of water column 06 to 0 Tests for CO must be made without a fire in the wood coal firebox and with all doors and draft controls completely closed The burner should be f...

Страница 19: ...of new home construction warranty co erage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authori ed HHT dealer distributor whiche...

Страница 20: ...warranty does not co er the following KDQJHV LQ VXUIDFH ILQLVKHV DV D UHVXOW RI QRUPDO XVH V D KHDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG exterior surface finishes may occur This is not a...

Страница 21: ...29 3 90 70744R11_05 13...

Страница 22: ...ach product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA Proudly Printed O...