manualshive.com logo in svg
background image

OPERATING INSTRUCTIONS

SMO112

WARM AIR OIL FIRED FURNACE

NOTICE TO HOMEOWNER

THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND

WHERE REQUIRED BY LAW, A LICENSED TECHNICIAN

Save These Instructions For Reference

Summeraire Mfg.

Peterborough, Ontario

K9J 7B1

FOR SERVICE CALL:

INSTALLATION INFORMATION

  ______________________________  

_____________________________  

            Installing Contractor                                                   Telephone Number

  ______________________________  

_____________________________

            Unit Model Number                                                     Unit Serial Number

  

 ________________________________

              

                Installation Date

NOTICE TO HOMEOWNER

IF YOUR SUMMERAIRE SMO112 OIL FURNACE HAS BEEN INSTALLED USING THE

APPROVED SS1-C TJERNLUND SIDEWALL POWER VENTOR; IT IS YOUR

RESPONSIBILITY TO KEEP THE AREA AROUND THE VENT TERMINAL FREE OF ICE,

SNOW, AND DEBRIS

SMO 112 FURNACES ARE AIR CONDITIONING READY!

OCT., 2007R

Содержание SMO112

Страница 1: ...__________________ _____________________________ Installing Contractor Telephone Number _ ______________________________ _____________________________ Unit Model Number Unit Serial Number _________________________________ Installation Date NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SMO112 OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS1 C TJERNLUND SIDEWALL POWER VENTOR IT IS YOUR RESPONSIBILITY ...

Страница 2: ...furnace Only qualified or where required by law a licensed technician shall set up this unit and adjust controls DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD Turn main oil burner switch to OFF Close a...

Страница 3: ...small rocker switch located on the power junction box MAINTENANCE OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service technician and where required by law a licensed technician CAUTION Do not use any commercially available soot remover Use extreme caution when servicing since the combustion chamber is fragile Routine clean...

Страница 4: ...g season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace are listed below DO NOT SUBSTITUTE Note Changing the type or size of filter used in your Summeraire furnace can seriously affect the op eration of the furnace AIR FILTER SPECIFICATIONS Filter size 20 X 20 x 1 CSA or ULC Certified Approved Type Throw away disposable USE OF FILTER...

Страница 5: ...air duct shall be circulated over the heat exchanger of the furnace 9 The owner must provide proof that the appliance has been serviced annually including annual cleaning of the complete furnace and inspection of the heat exchanger 10 The unit must not be installed in any structure where a corrosive atmosphere exists as may be found in dry cleaning establishments Laundromats Beauty Salons etc 11 S...

Отзывы: