OPERATING INSTRUCTIONS

CAUTION:

 NEVER BURN GARBAGE, REFUSE OR PAPER IN THE HEATING UNIT.

NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE.

NOTE: AN OPTIONAL VESTIBULE IS AVAILABLE FOR THE SMO112 FURNACE

             THE VESTIBULE COMPLETELY ENCLOSES THE OIL BURNER

IDENTIFY THE LOCATION OF YOUR BURNER / FURNACE POWER SWITCH

OIL BURNER OPERATING INSTRUCTIONS

•  Use No 2 furnace oil 

ONLY

•  Do not use gasoline, crankcase oil, or any oil containing gasoline.

•  Do not attempt to start the burner if excess oil has accumulated, when the furnace is full of vapor, 

or if the combustion chamber is hot.

•  Press the burner relay reset button ONLY ONCE; if the burner fails to start, call an 

Oil Burner Technician.

•  If the oil burner is to be shut off for any period of time, shut the oil valve OFF at the oil tank.

•  Do not adjust or tamper with the furnace or any of the controls

•  Do not burn garbage or paper in this unit.

•  Never leave paper, rags, or other combustibles around the furnace.

•  Only qualified, or where required by law, a licensed technician shall set – up this unit and 

adjust controls.

•  DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE.

TO TURN THE BURNER OFF 

•  Turn the main oil burner switch to “ OFF “ 

•  Set the thermostat as far below room temperature as possible.

IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD.

•  Turn main oil burner switch to “OFF”.

•  Close all oil supply valves.

•  The heating system should be checked and cleaned if necessary.

BURNER FAILS TO OPERATE

Always call a qualified technician

The trouble may be :

•  Raise your  thermostat to 5º C ( 10º F ) above present room temperature

•  Make sure your “ Oil Burner “ power switch is in the “ON” position

•  If you hear a hum from the oil burner, and the motor has not started, press the reset button 

on the burner motor once only.

•  Blown fuse  / “tripped” breaker in electrical panel 

•  Thermostat may be set below room temperature.

•  Burner relay ( combustion control ) may have to  be  “reset” ( press reset once only )

•  Oil valve may be closed.

•  Oil supply may be too low.

•  Blocked flue sensor “tripped”

•  If the oil burner fails to start or runs for only a few seconds, call a qualified service technician.

Содержание SMO112

Страница 1: ...__________________ _____________________________ Installing Contractor Telephone Number _ ______________________________ _____________________________ Unit Model Number Unit Serial Number _________________________________ Installation Date NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SMO112 OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS1 C TJERNLUND SIDEWALL POWER VENTOR IT IS YOUR RESPONSIBILITY ...

Страница 2: ...furnace Only qualified or where required by law a licensed technician shall set up this unit and adjust controls DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD Turn main oil burner switch to OFF Close a...

Страница 3: ...small rocker switch located on the power junction box MAINTENANCE OIL FURNACE ANNUAL SERVICE The oil burner and furnace should be thoroughly cleaned and serviced annually by a qualified service technician and where required by law a licensed technician CAUTION Do not use any commercially available soot remover Use extreme caution when servicing since the combustion chamber is fragile Routine clean...

Страница 4: ...g season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace are listed below DO NOT SUBSTITUTE Note Changing the type or size of filter used in your Summeraire furnace can seriously affect the op eration of the furnace AIR FILTER SPECIFICATIONS Filter size 20 X 20 x 1 CSA or ULC Certified Approved Type Throw away disposable USE OF FILTER...

Страница 5: ...air duct shall be circulated over the heat exchanger of the furnace 9 The owner must provide proof that the appliance has been serviced annually including annual cleaning of the complete furnace and inspection of the heat exchanger 10 The unit must not be installed in any structure where a corrosive atmosphere exists as may be found in dry cleaning establishments Laundromats Beauty Salons etc 11 S...

Отзывы: