SS-
AM9S80/AC9S80
www.amana-hac.com
3
AM9S80
0403A*
AM9S80
0603A*
AM9S80
0603B*
AM9S80
0604B*
AM9S80
0803B*
AM9S80
0804B*
AM9S80
0804C*
AM9S80
0805C*
AM9S80
1005C*
AM9S80
1205D*
Heating Capacity
Input
40,000
60,000
60,000
60,000
80,000
80,000
80,000
80,000
100,000
120,000
Natural Gas Output
32,000
48,000
48,000
48,000
64,000
64,000
64,000
64,000
80,000
96,000
LP Gas Output
32,000
48,000
48,000
48,000
64,000
64,000
64,000
64,000
80,000
96,000
AFUE ¹
80
80
80
80
80
80
80
80
80
80
Available AC @ 0.5” ESP
3
3
3
4
3
4
4
5
5
5
Temperature Rise Range (°F)
25-55
20-50
20-50
20-50
35-65
35-65
35-65
35-65
35-65
40-70
Circulator Blower
Size (D x W)
10" x 6"
10" x 6"
10" x 8"
10" x 8"
10" x 8"
10" x 8"
10" x 10"
10" x 10"
10" x 10"
10” x 10”
Horsepower @1075 RPM
0.5
0.5
0.5
0.75
0.5
0.75
0.75
0.75
0.75
1
Speed
9
9
9
9
9
9
9
9
9
9
Vent Diameter ²
4"
4"
4"
4"
4"
4"
4"
4"
4"
4"
No. of Burners
2
3
3
3
4
4
4
4
5
6
Electrical Data
Min. Circuit Ampacity ³
8.7
8.7
8.7
12.45
8.7
12.45
12.45
12.45
12.45
15.3
Max. Overcurrent Device (amps) ⁴
15
15
15
15
15
15
15
15
15
20
Ship Weight (lbs)
86
90
100
108
116
120
132
132
132
132
¹ DOE AFUE based upon Isolated Combustion System (ICS)
² Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code
NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).
³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with
National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁴ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size.
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
Gas Service Connection ½” FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.
AM9S80 Product Specifications