AM9S80/AC9S80
AC9S80 Product Specifications
AC9S80
0403A*
AC9S80
0603A*
AC9S80
0804B*
AC9S80
0805C*
AC9S80
1005C*
Heating Capacity
Input
40,000
60,000
80,000
80,000
100,000
Natural Gas Output
32,000
48,000
64,000
64,000
80,000
LP Gas Output
32,000
48,000
64,000
64,000
80,000
AFUE ¹
80
80
80
80
80
Available AC @ 0.5” ESP
3
3
4
5
5
Temperature Rise Range (°F)
25-55
30-60
35-65
35-65
40-70
Circulator Blower
Size (D x W)
10" X 6"
10" X 6"
10" X 8"
10" X 10"
10" X 10"
Horsepower @1075 RPM
1/2
1/2
3/4
1
1
Speed
9
9
9
9
9
Vent Diameter ²
4"
4"
4"
4"
4"
No. of Burners
2
3
4
4
5
Electrical Data
Min. Circuit Ampacity ³
8.7
8.7
12.45
15.3
15.3
Max. Overcurrent Device (amps) ⁴
15
15
15
20
20
Ship Weight (lbs)
90
94
107
115
115
¹ DOE AFUE based upon Isolated Combustion System (ICS)
² Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel
Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA
B142.2 (in Canada).
³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accor
-
dance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁴ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or
HACR-type circuit breakers of the same size as noted.
Notes
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
Gas Service Connection ½” FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code
and/or all existing local codes.