background image

SS-

AM9S80/AC9S80

www.amana-hac.com

19

Wiring Diagram

Wiring is subject t

o chang

e. Alw

ay

re

fer 

to 

the wiring 

diag

ram on 

the 

unit 

for the mos

t up-t

o-da

te 

wiring.

    

W

arning

High 

Volt

ag

e:

 Disc

onn

ect 

all 

po

w

er

 be

for

ser

vicing 

or 

in

st

alling 

this 

unit. 

Multiple 

po

w

er 

 

sour

ces 

ma

y be pr

esen

t. F

ailur

to do 

so ma

y c

ause pr

operty 

damag

e, 

per

sonal 

injur

y, 

or dea

th.

GN

GND

RD

GN

24

VAC

115

VAC

GND

GR
D

0140F02640-A

BK

EAC

HUMIDIFIER

ID

NEUTRAL

WIRING TO UNIT

L

INT

EG

RA

TE

D CO

NT

RO
L M

O

DUL
E

HOT SURFACE

GND

BLWR

NEUTRAL

WARNING:

GROUNDED.

OVERCURRENT PROTECTION DEVICE

MUST BE PROPERLY

SWITCH

NEUTRAL

ELECTRONIC

AIR

IGN

IND

DISCONNECT

FS

POLARIZED AND

NEUTRAL

LINE

NEUTRAL

JUNCTION BOX

BLWR

IND LO

N

INDOOR

AIR CLEANER

HUM

DOOR

NEUTRAL

INT

EG

RA

TE

D CO

NT

RO
L M

O

DUL
E

TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH

115 VAC

HUM-OUT

IGNITER

CIRCULATOR

BEFORE SERVICING.

FLAME SENSOR

DISCONNECT POWER

LINE

BR

W

H

GY

YL

PK

GY

LIMIT CONTROL

AUXILIARY

AUTO RESET

PK

WARNING:DISCONNECT

40 

VA

TR

AN

SF

O

RM

ER

N

G

C

SENSOR

FLAME

1 ROLL OUT SWITCH

SOME UNITS MAY HAVE

TO UNIT MUST BE

PU

BK

AND GROUNDED.

JU

NC

TIO

N

 B

O

X

W

H

BL

BR

NO

LIMIT CONTROL

AUTO RESET PRIMARY

WH

1

L

GY

BK

ID BLOWER PRESSURE SWITCH

SERVICING. WIRING

PK

RD

L

N

DOOR OPEN)

(OPEN WHEN

DOOR SWITCH

COMPARTMENT

BLOWER

GND

BLOWER

CIRCULATOR

Ø /60 HZ

DISCONNECT

GAS VALVE

OVERCURRENT

CONNECTOR

2 CIRCUIT

WH

CHASSIS

GROUND

IGNITER

SURFACE

HOT

2

YL

C

BLOWER

DRAFT

INDUCED

BK

BLOWER COMPARTMENT

115 VAC/ 1

BK

ECM MTR

HARNESS

POWER BEFORE

BK

TO
POWER SUPPLY WITH

BURNER COMPARTMENT

PROTECTION DEVICE

PROPERLY POLARIZED

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED

    WHEN SERVICING.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE

MUST BE REPLACED IT MUST BE REPLACED WITH  WIRING MATERIAL 

HAVING A TEMPERATURE RATING OF AT LEAST 105

v

 C. USE COPPER 

CONDUCTORS ONLY.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. 

    AND LOCAL CODES.

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, 

    DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY

    (NO THERMOSTAT INPUTS)

COLOR CODES:

PK PINK

BR BROWN

WH WHITE

BL BLUE

GY GRAY

RD RED

YL YELLOW

OR ORANGE

PU  PURPLE

GN GREEN

BK BLACK

1

2

3

4

5

6

7

8

9

10

11

12

READ CODES FROM LEFT TO RIGHT

EAC

-H

XF

MR
-H

CI

RC-
H

LIN

E-

H

E20

E39

E2

E1

E15

E8

E5

E4

E3

E7

E6

LE

FT

CEN

TE

R

RI

G

HT

SW3

3

1

3

1

3

SW1

R223

SW2

6

R226

RD

BL

RD

YL

YL

BK

BK

BK

W

H

W

H

W

H

GY

OR

GN

PU

PU

PU

NE

UT

2

NE

UT

1

CI

RC-
N

EAC

-N

HUM

-N

XF

MR
-N

LIN

E-

N

GND

MICRO

TO

TR (7)

G

C

C

TH (3)

24

V T

H

ERM
O

ST

AT

 CO
NNE
CT

IO

N

S   N.
E.C.

 CL
AS

S 2

 W

IRE

VALVE

GAS

HLI (8)

Y2

Y1

RLO (6)

O

MV (10)

W1

R

MANUAL RESET ROLLOUT LIMIT SWITCH

PRESS. SWITCH

C

DEHUM

PS1(5)

AUTO RESET

PRIMARY LIMIT

24 VAC

NO

HI

MVC (11)

BLWR

AIR

INDOOR

CIRCULATOR

R

TO

MICRO

TO

TO

+VDC

INTERGRATED CONTROL MODULE

RLI (12)

AUTO RESET AUX LIMIT

HLO (1)

Seven Segment Display

Error Code Status

Seg#3

Seg#2

Seg#1

Internal Faults or IRQ Loss

E

E

E

Lockout Due to Excessive Retries or Recycles

E

E

0

Pressure Switch Stuck Closed

E

E

1

Pressure Switch Open

E

E

2

Open High Limit Switch

E

E

3

Flame Detected When no Flame Should be Present

E

E

4

Open Fuse

E

E

5

Low Flame Signal

E

E

6

Ignitor Relay Fault

E

E

L

Reversed Line Polarity or Grounding Error

E

E

A

Internal Gas Valve Error

E

E

b

External Gas Valve Error

E

E

C

Open Rollout Switch

E

1

1

Ignitor Open

E

E

n

Inducer Relay Error

E

E

j

TWIN Error

E

E

H

RD

C

HI

1

2

BK

BK

BK

W

H

W

H

W

H

W

H

Grounding Error

E

1

0

5

2

1

4

3

RD

BK

OR

BL

YL

RD

BL

OR

BK

YL

T1

T2
T3
T4
T5

COM

RD

SWITCH (PRESS.)

FIELD SPLICE

FIELD GND

EQUIPMENT GND

       INTERNAL TO

PROT. DEVICE

INTEGRATED CONTROL

PLUG CONNECTION

SWITCH (TEMP.)

JUNCTION

LOW VOLTAGE (24V)

 OVERCURRENT

TERMINAL

IGNITER

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

HI VOLTAGE FIELD

GND

GND

TW

IN

24V

 H

UM

E21

E24

W/W1 R

Y/Y1

G C

Y2

TRANSFORMER

40 VA

Содержание AC9S80

Страница 1: ...ment District SCAQMD on or after October 1 2019 AHRI Certified ETL Listed Installation AM9S80 upflow horizontal left or right AC9S80 downflow horizontal left or right Convenient left or right connection for gas and electrical service Heavy gauge steel cabinet with durable baked enamel finish Foil faced insulated heat exchanger Contents Nomenclature 2 Product Specifications 3 Dimensions 5 Airflow D...

Страница 2: ...iguration NOx M Upflow Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM S Single Stage 3 1200 CFM 4 1600 CFM C Two Stage 5 2000 CFM AFUE MBTU h 80 80 AFUE 92 92 AFUE 030 30 000 BTU h 080 80 000 BTU hz 96 96 AFUE 97 97 AFUE 040 40 000 BTU h 100 100 000 BTU h 060 60 000 BTU h 120 120 000 BTU h ...

Страница 3: ...45 8 7 12 45 12 45 12 45 12 45 15 3 Max Overcurrent Device amps 15 15 15 15 15 15 15 15 15 20 Ship Weight lbs 86 90 100 108 116 120 132 132 132 132 DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canad...

Страница 4: ... upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be determined in accor dance ...

Страница 5: ...2 in Canada Note AMES80 approved for line contact in the horizontal position Model A B Model A B AM9S800403A 14 12 AM9S800804B 17 16 AM9S800603A 14 12 AM9S800804C 21 19 AM9S800603B 17 16 AM9S800805C 21 19 AM9S800604B 17 16 AM9S801005C 21 19 AM9S800803B 17 16 AM9S801205D 24 23 Notes Line voltage wiring can enter through the right or left side of furnace Low voltage wiring can enter through the righ...

Страница 6: ...500 ft natural gas operation are avail able Contact your Goodman distributor or dealer for details A B High Voltage Electrical Low Voltage Electrical Gas Inlet 19 28 11 18 33 Minimum Clearances to Combustible Materials Sides Rear Front Vent Top SW B 1 0 3 6 1 1 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the latest editions of the Nationa...

Страница 7: ...354 1332 1310 1288 AM9S80 0603B Y Y1 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 13...

Страница 8: ... 1733 1695 1655 1618 1576 AM9S80 0805C Y Y1 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055...

Страница 9: ... 1354 1332 1310 1288 AM9S80 0603B Y2 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 13...

Страница 10: ... 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 AM9S80 1005C Y2 F01 802 724 637 ...

Страница 11: ...1332 1310 1288 AM9S80 0603B G F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286...

Страница 12: ...3 1695 1655 1618 1576 AM9S80 0805C G F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2...

Страница 13: ...0803B W W1 F01 710 N A 646 N A 580 N A 515 N A 432 F02 1298 46 1255 47 1216 49 1178 50 1140 F03 1209 49 1166 51 1124 53 1083 55 1045 F04 1138 52 1091 54 1045 57 1001 59 959 AM9S80 0804B W W1 F01 841 N A 657 N A 595 N A 522 N A 439 F02 1141 52 1089 54 1045 57 1001 59 958 F03 1311 45 1267 47 1226 48 1189 50 1150 F04 1395 42 1347 44 1309 45 1270 47 1233 AM9S80 0804C W W1 F01 831 N A 750 N A 671 N A 5...

Страница 14: ...S80 0804B Y Y1 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 139...

Страница 15: ...1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 AC9S80 0805C Y2 F01 1022 813 674 585 511 431 334 282 ...

Страница 16: ...0804B G F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 AC9S8...

Страница 17: ...49 876 F03 932 48 887 50 844 53 806 55 767 F04 897 N A 851 N A 808 N A 764 N A 725 AC9S80 0804B W W1 F01 760 N A 697 N A 636 N A 569 N A 481 F02 1286 46 1238 48 1196 50 1157 51 1117 F03 1393 43 1348 44 1308 45 1270 47 1230 F04 1459 41 1414 42 1371 43 1336 44 1297 AC9S80 0805C W W1 F01 1022 N A 813 N A 674 N A 585 N A 511 F02 1453 41 1407 42 1332 45 1259 47 1190 F03 1176 N A 1105 N A 1020 N A 935 N...

Страница 18: ... BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Formulas BTU h Output CFRM x 1 08 x Rise Rise BTU H Output CFM CFM x 1 08 BTU h Output Vs Temperature Rise Chart Output BTU h x 1 000 ...

Страница 19: ...MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105v C USE COPPER CONDUCTORS ONLY 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES 5 TO RECALL THE LAST 6 FAULTS MOST RECENT TO LEAST RECENT DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY NO THERMOSTAT INPUTS COLOR CODES PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK ...

Страница 20: ...1 Downflow Sub Base 21 AFE18 60A Fossil Fuel Dual Fuel Kit HANG20 High Altitude Natu ral Gas Kit LPLP03 Low LP Gas Pressure Switch LPT 03 LP Conversion Kits Minimum Filter Sizes Model AM9S80 0403A AM9S80 0603A AM9S80 0604B AM9S80 0804B AM9S80 0805C AM9S80 81005C AM9S80 1205D Filter Size in 1 16 x 25 Side or 1 14 x 24 Bottom 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x...