background image

10

www.amana-hac.com

SS-

AM9S80/AC9S80

AM9S80 High Stage Cooling Airflow Data (Cont.)

Note:

 

^ DEFAULT SPEED

HIGH STAGE COOLING AIFLOW

MODEL

THER-

MO-

STAT 

CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

CFM

CFM

CFM

CFM

CFM

CFM

CFM

AM9S80

0804B*

 Y2

F01

841

657

595

522

439

367

315

N/A

F02

1141

1089

1045

1001

958

914

869

823

F03

1311

1267

1226

1189

1150

1114

1072

1034

F04

1395

1347

1309

1270

1233

1199

1164

1125

F05^

1490

1447

1407

1373

1336

1303

1269

1237

F06

1553

1510

1469

1435

1401

1368

1335

1300

F07

1593

1548

1508

1474

1440

1409

1376

1343

F08

1776

1735

1695

1661

1628

1601

1570

1542

F09

1853

1812

1773

1739

1708

1679

1650

1623

AM9S80

0804C*

 Y2

F01

831

750

671

588

501

405

348

300

F02

1214

1158

1103

1045

989

936

883

823

F03

1303

1249

1191

1136

1081

1028

974

928

F04

1426

1375

1324

1277

1229

1177

1124

1078

F05^

1518

1465

1418

1372

1328

1284

1237

1195

F06

1588

1539

1494

1447

1401

1358

1313

1267

F07

1710

1666

1632

1595

1554

1512

1473

1431

F08

1785

1751

1717

1675

1639

1596

1557

1516

F09

1845

1805

1771

1733

1695

1655

1618

1576

AM9S80

0805C*

 Y2

F01

837

752

671

576

501

426

361

315

F02

1316

1270

1218

1166

1114

1061

1000

962

F03

1353

1323

1286

1235

1183

1131

1085

1040

F04

1587

1544

1506

1459

1416

1372

1323

1281

F05^

1731

1673

1632

1587

1546

1506

1463

1421

F06

1794

1744

1709

1671

1632

1591

1555

1513

F07

1861

1805

1761

1720

1681

1642

1603

1565

F08

1910

1873

1839

1798

1761

1723

1686

1648

F09

2110

2055

2035

2003

1973

1946

1907

1890

AM9S80

1005C*

 Y2

F01

802

724

637

551

468

389

342

294

F02

1405

1356

1308

1262

1210

1182

1155

1102

F03

1574

1531

1484

1440

1392

1357

1306

1256

F04

1619

1575

1526

1489

1446

1404

1355

1313

F05^

1688

1641

1600

1557

1513

1477

1428

1381

F06

1811

1769

1730

1686

1649

1610

1572

1525

F07

1857

1812

1774

1733

1697

1662

1622

1586

F08

1892

1850

1805

1774

1735

1692

1658

1621

F09

2116

2073

2039

2005

1981

1945

1909

1879

AM9S80

1205D*

 Y2

F01

851

774

692

615

535

470

411

359

F02

1677

1629

1583

1540

1498

1449

1399

1349

F03

1537

1489

1444

1404

1365

1322

1272

1211

F04

1416

1365

1315

1267

1220

1163

1106

1048

F05^

1154

1098

1043

983

932

874

819

755

F06

1806

1764

1729

1688

1654

1615

1578

1535

F07

1869

1816

1773

1731

1693

1661

1629

1589

F08

1947

1903

1865

1833

1802

1769

1743

1708

F09

2107

2066

2030

1996

1963

1932

1899

1867

RECOMMENDED AIRFLOW SPEEDS FOR CONNECTION WITH 2 STAGE OUTDOOR MODELS

FURNACE MODEL

Y2

Y1

*M9S800805C*

F08

F02

*M9S801205D*

F06

F05

Содержание AC9S80

Страница 1: ...ment District SCAQMD on or after October 1 2019 AHRI Certified ETL Listed Installation AM9S80 upflow horizontal left or right AC9S80 downflow horizontal left or right Convenient left or right connection for gas and electrical service Heavy gauge steel cabinet with durable baked enamel finish Foil faced insulated heat exchanger Contents Nomenclature 2 Product Specifications 3 Dimensions 5 Airflow D...

Страница 2: ...iguration NOx M Upflow Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM S Single Stage 3 1200 CFM 4 1600 CFM C Two Stage 5 2000 CFM AFUE MBTU h 80 80 AFUE 92 92 AFUE 030 30 000 BTU h 080 80 000 BTU hz 96 96 AFUE 97 97 AFUE 040 40 000 BTU h 100 100 000 BTU h 060 60 000 BTU h 120 120 000 BTU h ...

Страница 3: ...45 8 7 12 45 12 45 12 45 12 45 15 3 Max Overcurrent Device amps 15 15 15 15 15 15 15 15 15 20 Ship Weight lbs 86 90 100 108 116 120 132 132 132 132 DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canad...

Страница 4: ... upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be determined in accor dance ...

Страница 5: ...2 in Canada Note AMES80 approved for line contact in the horizontal position Model A B Model A B AM9S800403A 14 12 AM9S800804B 17 16 AM9S800603A 14 12 AM9S800804C 21 19 AM9S800603B 17 16 AM9S800805C 21 19 AM9S800604B 17 16 AM9S801005C 21 19 AM9S800803B 17 16 AM9S801205D 24 23 Notes Line voltage wiring can enter through the right or left side of furnace Low voltage wiring can enter through the righ...

Страница 6: ...500 ft natural gas operation are avail able Contact your Goodman distributor or dealer for details A B High Voltage Electrical Low Voltage Electrical Gas Inlet 19 28 11 18 33 Minimum Clearances to Combustible Materials Sides Rear Front Vent Top SW B 1 0 3 6 1 1 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the latest editions of the Nationa...

Страница 7: ...354 1332 1310 1288 AM9S80 0603B Y Y1 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 13...

Страница 8: ... 1733 1695 1655 1618 1576 AM9S80 0805C Y Y1 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055...

Страница 9: ... 1354 1332 1310 1288 AM9S80 0603B Y2 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 13...

Страница 10: ... 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 AM9S80 1005C Y2 F01 802 724 637 ...

Страница 11: ...1332 1310 1288 AM9S80 0603B G F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286...

Страница 12: ...3 1695 1655 1618 1576 AM9S80 0805C G F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2...

Страница 13: ...0803B W W1 F01 710 N A 646 N A 580 N A 515 N A 432 F02 1298 46 1255 47 1216 49 1178 50 1140 F03 1209 49 1166 51 1124 53 1083 55 1045 F04 1138 52 1091 54 1045 57 1001 59 959 AM9S80 0804B W W1 F01 841 N A 657 N A 595 N A 522 N A 439 F02 1141 52 1089 54 1045 57 1001 59 958 F03 1311 45 1267 47 1226 48 1189 50 1150 F04 1395 42 1347 44 1309 45 1270 47 1233 AM9S80 0804C W W1 F01 831 N A 750 N A 671 N A 5...

Страница 14: ...S80 0804B Y Y1 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 139...

Страница 15: ...1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 AC9S80 0805C Y2 F01 1022 813 674 585 511 431 334 282 ...

Страница 16: ...0804B G F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 AC9S8...

Страница 17: ...49 876 F03 932 48 887 50 844 53 806 55 767 F04 897 N A 851 N A 808 N A 764 N A 725 AC9S80 0804B W W1 F01 760 N A 697 N A 636 N A 569 N A 481 F02 1286 46 1238 48 1196 50 1157 51 1117 F03 1393 43 1348 44 1308 45 1270 47 1230 F04 1459 41 1414 42 1371 43 1336 44 1297 AC9S80 0805C W W1 F01 1022 N A 813 N A 674 N A 585 N A 511 F02 1453 41 1407 42 1332 45 1259 47 1190 F03 1176 N A 1105 N A 1020 N A 935 N...

Страница 18: ... BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Formulas BTU h Output CFRM x 1 08 x Rise Rise BTU H Output CFM CFM x 1 08 BTU h Output Vs Temperature Rise Chart Output BTU h x 1 000 ...

Страница 19: ...MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105v C USE COPPER CONDUCTORS ONLY 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES 5 TO RECALL THE LAST 6 FAULTS MOST RECENT TO LEAST RECENT DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY NO THERMOSTAT INPUTS COLOR CODES PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK ...

Страница 20: ...1 Downflow Sub Base 21 AFE18 60A Fossil Fuel Dual Fuel Kit HANG20 High Altitude Natu ral Gas Kit LPLP03 Low LP Gas Pressure Switch LPT 03 LP Conversion Kits Minimum Filter Sizes Model AM9S80 0403A AM9S80 0603A AM9S80 0604B AM9S80 0804B AM9S80 0805C AM9S80 81005C AM9S80 1205D Filter Size in 1 16 x 25 Side or 1 14 x 24 Bottom 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x...

Отзывы: