AM9S80/AC9S80
www.amana-hac.com
5
AM9S80 Dimensions
28”
A
B
1¾”
33⅜”
23
5⁄16
”
1
7⁄16
”
13¼”
20”
27⅞”
Alt. Gas Inlet
Alt. High Voltage
Alt. Low Voltage
Alternate Gas Inlet
High-Voltage Inlet
Low-Voltage Inlet
Alt. Flue Outlet — Horizontal Left
➤
19½”
➤
➤
23”
➤
➤
15”
➤
➤
Minimum Clearances to Combustible Materials
Sides
Rear
Front¹
Vent²
Top
SW
B
1”
0”
3”
6”
1”
1”
¹ 24” clearance for serviceability recommended.
² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas
Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and
CAN/CSA B142.2 (in Canada).
Note: AMES80 approved for line contact in the horizontal position.
Model
A
B
Model
A
B
AM9S800403A*
14”
12½”
AM9S800804B*
17½”
16”
AM9S800603A*
14”
12½”
AM9S800804C*
21”
19½”
AM9S800603B*
17½”
16”
AM9S800805C*
21”
19½”
AM9S800604B*
17½”
16”
AM9S801005C*
21”
19½”
AM9S800803B*
17½”
16”
AM9S801205D*
24½”
23”
Notes
•
Line voltage wiring can enter through the right or left side of furnace.
Low-voltage wiring can enter through the right or left side of furnace.
•
Conversion kits for high-altitude (4500+ ft) natural gas operation are available.
Contact your Goodman distributor or dealer for details.
•
Installer must supply the following gas line fittings, according to which entrance is used:
Left: One 90º street elbow; one 2½” pipe nipple; one 90º elbow; straight pipe; one ground joint union
Right: Straight pipe to reach gas valve