APPENDIX E: COMMUNICATIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
E-4
990-412
Protocol
Single-directional Communication Mode
(When
-->
is selected at
COMM CONTROL
in
MODE SELECT Screen
)
1) Monitor Data
IS-2200CA/4500CA BASIC Data strings:
!01 001 :m, 120, 1.20, 0.50, 00.60, 20.0, 200, 2.00, 1.50, 03.00, 40.0, 300, 2.50,
Continued on
next line
A B C
D E
F
G
H
I
J
K
L
M
N
O
2.00, 05.00, 50.0, 2, 0010, 5, 0100, 2222, 555555 [CR][LF]
P
Q
R S
T U V
W
X
IS-1200CA/4500CA ADVANCED Data strings:
!01 001 :m, 120, 01.20, 0.50, 00.60, 20.0, 200, 02.00, 1.50, 03.00, 40.0, 300, 02.50,
Continued on
next line
A B C
D E
F
G
H
I
J
K
L
M
N
O
2.00, 05.00, 50.0, 2, 0010, 5, 0100, 1, 0000, 1, 0000, 01, 100, 0100, 2222, 555555,
Continued on
next line
P
Q
R S
T U V W
X Y
Z AA AB AC AD
AE
05000, 05000, 05000, 05000, 05000, 05000, +00.100, +01.120, [CR][LF]
AF
AG
AH
AI
AJ
AK
AL
AM
A
Device No.
Fixed to 2 digits (01 to 31)
B
Schedule No.
Fixed to 3 digits (001 to 255)
C
Unit of monitor time
m: ms
C: CYC
D
Monitor time of WE1
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
E
Monitor current of WE1
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
F
Monitor voltage of WE1
Fixed to 4 digits (0.00 to 9.99) (V)
G
Monitor power of WE1
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 999.9) (kW)
H
Monitor pulse width of WE1
Fixed to 4 digits (10.0 to 99.9) (%)
I
Monitor time of WE2
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
J
Monitor current of WE2
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
K
Monitor voltage of WE2
Fixed to 4 digits (0.00 to 9.99) (V)
L
Monitor power of WE2
Fixed to 5 digits (00.00 to 09.99) (kW)
Fixed to 5 digits (000.0 to 999.9) (kW)
M
Monitor pulse width of WE2
Fixed to 4 digits (10.0 to 99.9) (%)
N
Monitor time of WE3
Fixed to 3 digits (000 to 999) (ms)
Fixed to 3 digits (000 to 050) (CYC)
O
Monitor current of WE3
Fixed to 4 digits (0.00 to 9.99) (kA)
Fixed to 4 digits (00.0 to 99.9) (kA)
Содержание S-2200CA
Страница 1: ...990 412 REV G INVERTER POWER SUPPLY IS 2200CA 4500CA OPERATION MANUAL...
Страница 20: ......
Страница 31: ...CHAPTER 1 SYSTEM DESCRIPTION IS 2200CA 4500CA INVERTER POWER SUPPLY 990 412 1 11...
Страница 38: ......
Страница 114: ......
Страница 136: ......
Страница 168: ......
Страница 210: ...AMADA WELD TECH INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...