CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-47
13. I/O CHECK Screen
This screen is used to check the status of the external I/O signals. The “*” symbol appears when
the corresponding input signal is ON. The asterisk disappears if the signal is OFF. Set the cursor
reading to “0” to turn OFF the output signal, and “1” to turn it ON. Reception of an input signal
while this screen is showing will not activate the corresponding function. You cannot move to
another screen while the 1ST or 2NDSTAGE signal is input.
I/O Terminal Board (see Appendix B for user accessible I/O’s)
Input signal
SCHEDULE 1
SCHEDULE 128
ERROR RESET
SCHEDULE 2
PARITY
STEP RESET
SCHEDULE 4
WELD COUNT
COUNT RESET
SCHEDULE 8
WELD CONT
STAGE 1
SCHEDULE 16
THERMOSTAT
STAGE 2
SCHEDULE 32
FLOW SWITCH
RETRACTION 1
SCHEDULE 64
BACK STEP
RETRACTION 2
STEP MODE
Output signal
NG1 OUT (ERROR)
VALVE1 (SOL1)
NG2 OUT (CAUTION)
VALVE2 (SOL2)
OUT1
EX VALVE1 (EX SOL1)
OUT2
EX VALVE2 (EX SOL2)
OUT3
EX VALVE3 (EX SOL3)
OUT4
EX VALVE4 (EX SOL4)
OUT5
RET VALVE1 (RET SOL1)
RET VALVE2 (RET SOL2)
VALVE RELAY (SOL RELAY)