CHAPTER 4: OPERATING INSTRUCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
4-4
990-412
Section III: Shutdown
CAUTION
DO NOT power ON the unit while the door is open. Touching anything inside the cabinet with power ON
may cause death.
Turn the Power Supply OFF
The IS-2200CA requires to turn the power handle to OFF to open the cabinet. This will trip the breaker,
cut power to the inside of the cabinet and discharge the capacitors within 30 seconds.
Push the OFF button on the circuit breaker to power the system down.
Note:
The IS-4500CA has an interlock system. A soon as anyone opens the door, the breaker will trip,
cutting power to the inside of the cabinet and automatically discharge the capacitors within 30 seconds.
Wait 10 minutes before conducting any work inside the cabinet AFTER power is turned off.