Chapter
9
60
ML-73
□□
EL
Chapter
9
Serial Interface Specifications
(14) SRR/SRW (Serial)
Obtain the existing serial information and change or set.
The settings are given below.
■
Read (SRR s0)
■
Write (SRW t0, t1, t2, t3, t4, t5, t6, t7, t8)
(15) VDR/VDW (Variable data)
Obtain (read) the existing variable data.
Also used to revise or set (write) existing variable data decompressed in RAM.
■
Read (VDR s0)
s0: Variable data no.
Specify 0 to obtain the registered variable data numbers delimited by commas.
s0
Serial number
(Specify 0 to obtain the registered serial numbers delimited by commas.)
t1
Digits
t2
Current value (Suppress Zeros = ON)
t3
Value of increase and decrease
t4
Suppress Zeros (0: OFF, 1: ON)
t5
Minimum (Suppress Zeros = ON)
t6
Maximum (Suppress Zeros = ON)
t7
Alarm output (0: OFF, 1: ON)
t8
Clear input (0: OFF, 1: ON)
The Suppress Zeros (t4) setting will be applied when the serial number is actually
marked. It is not related to how the present value (t2), minimum value (t5), and
maximum value (t6) are displayed.
Computer ->
Marker
: SRR1
(Change 1 to 0 to have the marker return the registered serial
numbers delimited by commas.)
Marker ->
Computer
: t1, t2, t3, t4, t5, t6, t7, t8
Example
When setting information for serial #7 as follows: Digits = 5, Current value = 3333, Value of increase/
decrease = -1, Suppress Zeros = ON,
Minimum = 0, Maximum = 99999, Alarm output = ON, Clear input = OFF
Computer ->
Marker
: SRW7, 5, 3333, -1, 1, 0, 99999, 1, 0
Example
When obtaining the value of variable data #1, which is ABC in the 1st standard font
Computer ->
Marker
: VDR1
(Change 1 to 0 to have the marker return the registered
variable data numbers delimited by commas.)
Marker ->
Computer
: 0, ABC
Содержание ML-73 EL Series
Страница 1: ...Z11OM1209102 02 Fiber Laser Marker ML 73 EL OPERATION MANUAL Original instructions...
Страница 4: ......