Aligning the PRO-S CPE’s Antenna
BreezeMAX CPEs Product Manual
63
3
From the Pocket PC/Notebook, connect to the SU and complete the process of
configuring basic parameters.
4
Verify that the the unit is synchronized with a Base Station. If the SU is not
synchronized with a Base Station, ensure that all parameters are configured
properly. If the unit is still not synchronized with a Base Station, improve the
quality of the link by changing the direction of the antenna or by placing the
antenna at a higher or in an alternate location.
5
Rotate (and/or tilt if applicable) the ODU/antenna until the maximum link
quality (SNR and RSSI) reading is achieved. If you encounter prolonged
difficulty in achieving the expected link quality, try to improve the reception
quality by placing the antenna at a higher point or in an alternate location.
6
Secure the ODU/antenna firmly to the pole.
3.3.2
SU Alignment Unit (SAU)
The miniature SU Alignment Unit can be used during installation and testing to
support an easy process of antenna alignment and provide the ODU's status
indications.
1
Remove the sealing cap of the ODU's SAU connector.
NOTE
When the Y-Cable is connected, there is no Ethernet connectivity between the ODU and the data
device connected to the IDU.
NOTE
Ensure that the front of the antenna is always facing the Base Station. However, in certain
conditions, such as when the line of sight to the Base Station is hampered, better reception may be
achieved using a reflected signal. In this case, the antenna is not necessarily directed toward the
Base Station.
CAUTION
In some cases, the antenna may need to be tilted to ensure that the level at which the SU receives
transmissions from the AU (and vice versa) is not too high. When the RSSI reading is higher than
-20 dBm, the received signal level is too high (saturation). This must be avoided, preferably by
up-tilting the antenna. As a rule of thumb, if the SU is located at a distance of less than 300 meters
from the AU, it is recommended to up-tilt the antenna by approximately 10° to 15°.
To connect the SAU to the ODU:
Содержание BreezeMAX PRO-S CPE
Страница 1: ...BreezeMAX CPEs Product Manual SW Version 4 5 May 2008 P N 214974...
Страница 12: ......
Страница 20: ...xx BreezeMAX CPEs Product Manual Figures Figure A 2 Web Configuration Main Menu Pocket PC PDA 119...
Страница 40: ......
Страница 78: ......
Страница 145: ...B Appendix B Troubleshooting In This Chapter Si CPE Troubleshooting on page 124 PRO S CPE Troubleshooting on page 128...
Страница 162: ......