106
BreezeMAX CPEs Product Manual
Chapter 4 - Operation
Stop Scanning
Exit Spectrum mode
4.9.3.1
Start Frequency
The first frequency (in MHZ) participating in the test. Must be in the range
supported by the unit.
4.9.3.2
Stop Frequency
The highest frequency (in MHz) that may participate in the test (the actuall
highest frequency depends on the defined Start Frequency and Scanning Step).
Must be in the range supported by the unit.
4.9.3.3
Scanning Step
The scanning step size. The available options are:
1 - 1.75 MHz
2 - 3.5 MHz
3 - 2.5 MHz
4 - 5 MHz
The scanned frequencies are defined by Start Fre N*Scanning Step where
N is 0, 1, 2...and the scanned frequency is lower than or or equal to the Stop
Frequency.
4.9.3.4
Single Freq Scanning Duration
The test duration in seconds at each of the scanned frequencies. The available
range is from 1 to 65535 seconds.
4.9.3.5
Antenna to be tested
The antenna(s) to be tested during the test: external (0), internal (1 - 6) or all (7).
4.9.3.6
Show parameters
Select this option to view the current values of the test parameters.
Содержание BreezeMAX PRO-S CPE
Страница 1: ...BreezeMAX CPEs Product Manual SW Version 4 5 May 2008 P N 214974...
Страница 12: ......
Страница 20: ...xx BreezeMAX CPEs Product Manual Figures Figure A 2 Web Configuration Main Menu Pocket PC PDA 119...
Страница 40: ......
Страница 78: ......
Страница 145: ...B Appendix B Troubleshooting In This Chapter Si CPE Troubleshooting on page 124 PRO S CPE Troubleshooting on page 128...
Страница 162: ......