Si CPE Troubleshooting
BreezeMAX CPEs Product Manual
127
Authentication Failure:
STATUS LED is blinking
green, SIGNAL LED 7 is
on, all other SIGNAL LEDs
are off.
Authentication problem:
a. Wrong User Name
and/or User Password.
b.Maximum number of
Multiple Sessions (number
of SUs that can receive the
Service simultaneously)
has been reached.
Enter User Name and User Password and reset the
unit. If the problem persists, contact the operator.
Duplicate Name: STATUS
LED is blinking green,
SIGNAL LEDs 6 and 7 are
on, all other SIGNAL LEDs
are off.
User Name already exists
in the Base Station’s
database, associated with
another SU (MAC address)
Enter a correct User Name or contact the operator
for a new User Name/Password. Reset the unit after
configuring new authentication parameters.
Authentication Timeout:
STATUS LED is blinking
green, SIGNAL LEDs 5, 6
and 7 are on, all other
SIGNAL LEDs are off.
The unit was not
reauthenticated after
authentication timeout.
Contact the operator.
Problem and Indication
Possible Cause
Corrective Action
Содержание BreezeMAX PRO-S CPE
Страница 1: ...BreezeMAX CPEs Product Manual SW Version 4 5 May 2008 P N 214974...
Страница 12: ......
Страница 20: ...xx BreezeMAX CPEs Product Manual Figures Figure A 2 Web Configuration Main Menu Pocket PC PDA 119...
Страница 40: ......
Страница 78: ......
Страница 145: ...B Appendix B Troubleshooting In This Chapter Si CPE Troubleshooting on page 124 PRO S CPE Troubleshooting on page 128...
Страница 162: ......