Indoor SU-I and AU-I Units
3-5
BreezeACCESS Version 4.5 System Manual
capabilities. By using two antennas per unit, the system can select the
best antenna on a per-packet basis (every several milliseconds).
When installing a single antenna, configure the
Transmit Antenna
option to either
Antenna 1
or
Antenna 2
, according to the antenna
being used. When using two antennas, configure the
Transmit
Antenna
option to
Both Antennas
.
Antenna Polarization
Antenna polarization must be the same at either end of the link. In most
applications, the preferred orientation is vertical polarization. Above
ground propagation of the signal is better when it is polarized vertically.
For omni antennas, make sure that the antennas are extended upward
vertically in relation to the floor to achieve vertical polarization. To verify
polarization of detached antennas, refer to the assembly instructions
supplied with the antenna set.
Antenna Seal
When using outdoor antennas, you must seal the antenna connectors
against rain. Otherwise the antennas are not suitable for use in outdoor
installations.
Lightning Protection
Lightning protection is designed to protect people, property and
equipment by providing a path to ground for the lightning’s energy. The
lightning arrestor diverts the strike energy to the ground along a
deliberate and controlled path instead of allowing it to choose a random
path. Lightning protection for a building is more forgiving than
protection of electronic devices. A building can withstand up to 100,000
volts, but electronic equipment may be damaged by just a few volts.
Lightning protection entails connecting an antenna discharge unit (also
called an arrestor) to each cable as close as possible to the point where
it enters the building. It also entails proper grounding of the arrestors
and of the antenna mast (if the antenna is connected to one).
The lightning arrestor should be installed and grounded at the point
where the cable enters the building. The arrestor is connected to the
unit at one end and to the antenna at the other end.
The professional installer you choose must be knowledgeable about
lightning protection. The installer must install the lightning protector in
a way that maximizes lightning protection.
AL 1 Lightning Arrestor - Part No. 872905 5 ft (1.5m), “N” Male to “N”
Female is available from Alvarion.
Содержание BreezeACCESS II
Страница 1: ...BreezeACCESS II System Manual SW Version 4 5 June 2004 P N 213801 ...
Страница 2: ......
Страница 15: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 1 System Description ...
Страница 16: ......
Страница 32: ...2 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Страница 46: ...3 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Страница 47: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 2 Installation ...
Страница 48: ......
Страница 80: ...2 8 BreezeACCESS Version 4 5 Installation Manual Revision 1 0 ...
Страница 93: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 3 Commissioning ...
Страница 94: ......
Страница 110: ...2 8 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Страница 116: ...3 6 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Страница 125: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 4 Operations and Administration ...
Страница 126: ......
Страница 257: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Appendices ...
Страница 258: ......
Страница 268: ...D 2 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 110 68 151 32 111 67 152 31 112 66 153 30 113 65 ...
Страница 270: ...D 4 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 ...
Страница 324: ...1 14 BreezeACCESS Version 4 5 Index Manual Revision 1 0 ...