Menus and Parameters
2-89
BreezeACCESS Version 4.5 System Manual
!
Interference Avoidance Parameters:
These parameters enable to
define the interference avoidance algorithm. The algorithm is
designed to minimize the probability of the modem identifying
interference as a possible desired signal. Such an occurrence should
be avoided, as locking on the interfering signal may disable the
modem from timely identifying the appearance of a desired signal.
Setting a certain level as a threshold below which signal are
considered as interference is not sufficient, since the energy in the
relevant spectrum of interfering signals may temporarily be well
above the threshold level. On the other hand, setting the threshold
at a higher level to overcome the effect of temporary occurrences of
high-level interferences is not a good solution, as it may cause the
unit to reject desired signals. The solution is a dynamic decision
algorithm that will follow temporary high-level interferences and
adjust the decision threshold accordingly.
The algorithm for identifying transmissions of messages initiated by
another unit includes two settable parameters:
Noise Floor
and
Carrier to Interference Difference Level
.
The
Noise Floor
parameter represents the equivalent noise level in
the neighborhood of the unit, including both the thermal noise and
average level of interference in the relevant spectrum.
Carrier to Interference Difference Level
is the minimal difference
between the level that is defined as the
Current Noise Level
and the
level of a “good” signal (a signal that the unit should treat as a
possibly desired signal).
The modem of the unit continuously estimates the level of the
received energy at the relevant spectrum. The
Current Noise Floor
is defined as follows:
If the last estimated energy level was lower than or equal to the
Noise Floor
, then the
Current Noise Floor
is equal to the
Noise
Floor
.
If the last estimated level was above the
Noise Floor
, it can be either
interference or a possibly “good” signal. If it is lower than the last
Current Noise Floor
, or if the difference from the last
Current
Noise Floor
is less than the
Carrier to Interference Difference
Level
, it shall be considered as interference and it becomes the
updated
Current Noise Floor.
Carrier to Interference Difference Level
is the minimal difference
between the
Current Noise Floor
and the level of a signal that will
be defined as a “good” one.
This means that the actual threshold to be used for decision on the
existence of a valid signal is the higher of the following two levels:
a. Carrier Sense Level
b. “Current Noise Floor” + Carrier to Interference Difference Level.
This algorithm allows the unit to identify and track temporary high
level interference and to adjust the decision threshold accordingly.
Содержание BreezeACCESS II
Страница 1: ...BreezeACCESS II System Manual SW Version 4 5 June 2004 P N 213801 ...
Страница 2: ......
Страница 15: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 1 System Description ...
Страница 16: ......
Страница 32: ...2 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Страница 46: ...3 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Страница 47: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 2 Installation ...
Страница 48: ......
Страница 80: ...2 8 BreezeACCESS Version 4 5 Installation Manual Revision 1 0 ...
Страница 93: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 3 Commissioning ...
Страница 94: ......
Страница 110: ...2 8 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Страница 116: ...3 6 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Страница 125: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 4 Operations and Administration ...
Страница 126: ......
Страница 257: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Appendices ...
Страница 258: ......
Страница 268: ...D 2 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 110 68 151 32 111 67 152 31 112 66 153 30 113 65 ...
Страница 270: ...D 4 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 ...
Страница 324: ...1 14 BreezeACCESS Version 4 5 Index Manual Revision 1 0 ...