Appendix B
B-5
BreezeACCESS Version 4.5 System Manual
When loading is completed the following message is displayed:
Loading
operation has been completed successfully
.
The FLASH memory can store two software versions. One version is
called
Current
and the second version is called
Shadow
. The new
version is loaded into the Shadow (backup) FLASH memory.
To check that the new firmware was loaded properly, view the firmware
versions stored in the FLASH using the following procedure:
1.
From the
Main Menu
, select
2 – Unit Control
.
The Unit Control menu opens.
2.
From the
Unit Control
menu, select
5 – Flash Memory Control
.
The
Flash Memory Control
menu opens.
3.
From the
Flash Memory Control
menu, select
S – Show Flash
Versions
.
The display appears as follows:
Flash Versions
===========
Current Version:
3.0.39
Shadow Version:
4.0.40
Version After Reset:3.0.39
From the
Flash Memory Control
menu select the active software version,
using the following procedures:
To activate the backup (shadow) version:
1.
From the
Flash Memory Control
menu select
1 - Reset and Boot
from
Shadow Version
.
The
Reset and Boot from Shadow Version
menu opens.
2.
Select
1 – Reset Now
and press ENTER.
3.
The unit resets and the Shadow version is used as the newactive
version. Note that after the next reset, the Current version will be
activated again.
If the active version is the Shadow version and you wish to
continue using it after the next Reset, use the following procedure:
NOTE:
If you are upgrading a Subscriber Unit which is not associated with an AU, the unit will
reset every five minute (approximately) and the following message will be displayed:
FTL: file src\wpscan.c line 262 Too large number of scanning
attempts
The unit will reset and it will take more than a minute before you can re-establish the
connection to it. You should either have the SU associated with an AU before starting
the loading process or complete the loading process before the unit resets. Otherwise
you will have to try again until you complete the loading process.
Содержание BreezeACCESS II
Страница 1: ...BreezeACCESS II System Manual SW Version 4 5 June 2004 P N 213801 ...
Страница 2: ......
Страница 15: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 1 System Description ...
Страница 16: ......
Страница 32: ...2 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Страница 46: ...3 14 BreezeACCESS Version 4 5 System Description Manual Revision 1 0 ...
Страница 47: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 2 Installation ...
Страница 48: ......
Страница 80: ...2 8 BreezeACCESS Version 4 5 Installation Manual Revision 1 0 ...
Страница 93: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 3 Commissioning ...
Страница 94: ......
Страница 110: ...2 8 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Страница 116: ...3 6 BreezeACCESS Version 4 5 Commissioning Manual Revision 1 0 ...
Страница 125: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Book 4 Operations and Administration ...
Страница 126: ......
Страница 257: ...BreezeACCESS II SW Version 4 5 Revision 1 0 System Manual Appendices ...
Страница 258: ......
Страница 268: ...D 2 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 110 68 151 32 111 67 152 31 112 66 153 30 113 65 ...
Страница 270: ...D 4 BreezeACCESS Version 4 5 System Manual Manual Revision 1 0 ...
Страница 324: ...1 14 BreezeACCESS Version 4 5 Index Manual Revision 1 0 ...