Gas Fryer Operation & Care Manual • 8
I N S T A L L A T I O N
The Alto-Shaam open gas fryer has been set to operate
with either natural gas or propane as indicated on the
fryer identification name plate.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2
psi. The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi.
NOTE:
Customer/installer must provide manual gas shut-
off valve in accordance with local code
requirements.
G A S P R E S S U R E C H A R T
The fryer has been factory adjusted according to
the gas type specified on the fryer identification
name plate.
GAS FRYER TECHNICAL SPECIFICATIONS
N a t u r a l G a s
Min. Connected Pressure
5.0" W.C.
1.2 kPa
Max. Connected Pressure
14.0" W.C.
3.5 kPa
Gas Consumption
120 CFM
Gross Thermal Output
120,000 Btu/hr
P ro p a n e G a s
Min. Connected Pressure
10.0" W.C.
2.5 kPa
Max. Connected Pressure
14.0" W.C.
3.5 kPa
Gas Consumption
48 CFM
Gross Thermal Output
120,000 Btu/hr
I N S TA L L AT I O N R E Q U I R E M E N T S
GAS CONNECTION
: 1/2
" NPT
CHECK PLUMBING CODES FOR PROPER SUPPLY LINE SIZING TO
ATTAIN MINIMUM BURNER MANIFOLD PRESSURE SHOWN
:
NATURAL GAS
: 5.0" W.C.
PROPANE GAS
: 10.0" W.C.
MAXIMUM INLET PRESSURE
: 14" W.C.
NOTE:
If a flexible gas line is used, it must be AGA
approved, commercial type and at least 3/4" I.D.
HOOD INSTALLATION IS REQUIRED
G A S S P E C I F I C AT I O N S
■
■
NATURAL GAS
■
■
PROPANE GAS
120,000 BTU/hr.
INPUT
120,000 BTU/hr.
INPUT
G A S S P E C I F I C A T I O N S
D A N G E R
CONNECTING TO THE WRONG GAS
SUPPLY COULD RESULT IN FIRE OR
AN EXPLOSION CAUSING SEVERE
INJURY AND PROPERTY DAMAGE.
W A R N I N G
TO AVOID SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition of
the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes. In
Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.
Содержание FryTech ASF-60G
Страница 65: ...Gas Fryer Operation Care Manual 64 A S F 7 5 G S E R V I C E...
Страница 66: ...Gas Fryer Operation Care Manual 65 A S F 7 5 G S E R V I C E...
Страница 67: ...Gas Fryer Operation Care Manual 66 A S F 7 5 G S E R V I C E...
Страница 68: ...Gas Fryer Operation Care Manual 67 A S F 7 5 G S E R V I C E...
Страница 69: ...Gas Fryer Operation Care Manual 68 A S F 6 0 G S E R V I C E...
Страница 70: ...Gas Fryer Operation Care Manual 69 A S F 6 0 G S E R V I C E...
Страница 71: ...Gas Fryer Operation Care Manual 70 A S F 6 0 G S E R V I C E...
Страница 72: ...Gas Fryer Operation Care Manual 71 A S F 6 0 G S E R V I C E...