Gas Fryer Operation & Care Manual • 13
O P E R A T I O N
NOTE:
Perform an initial Boil-Out to clean and
sanitize the fryer station before
operating. (See page 15.)
1.
Service is to be performed by an authorized
Alto-Shaam service agent.
2.
Ensure all local electrical codes, fire codes, and
all other requirements such as hood installation
have been met in the process of installation.
NOTE:
Because each fryer station is controlled
separately, the following procedures
must be followed for every component
fryer in multiple-station units.
3.
Open front access door and ensure drain valve is
closed.
The handle should be rotated clockwise
until it stops.
4.
Fill frypot with frying compound as indicated.
(
SEE ILLUSTRATION ON THE OIL
/
SHORTENING REQUIREMENTS
PAGE
)
5.
The Master Power Switch is located behind the
front access door. Turn Master Power Switch
“ O N . ”
6.
Press
E L E M E N T H I R E S E T
button.
7.
The
L E D
display on the basic control panel will
indicate
“ - A S - ”
, the software version, and then
“ C Y ”
.
8.
When the fryer has reached 135°F, the melt cycle
is complete and the
L E D
display on the control
panel will indicate
“ H E A t ”
.
9.
When the fryer displays the set-point
temperature, product can be fried.
10.
More detailed operating guidelines along with
information on programming are located within
this manual.
11.
To shutdown the fryer, turn the Master Power
Switch located behind the front access door to
the
“ O F F ”
position.
NOTE:
F O R
Y O U R
P R O T E C T I O N
The fryer station is
furnished with a hi-limit safety shutoff that
will disengage the control if the frying
compound temperature in the frypot would
ever exceed 415°F (213°C). The
L E D
will
display
“ H i ”
, the heat will shut off, the
timer will be cancelled, and a constant alarm
will sound. In this event, allow the frying
compound temperature to drop below 415°F
(213°C). Open the front access door and
press the
OIL HI-LIMIT RESET
button for
a period of 3-seconds to restart the control.
B A S I C C O N T R O L S T A R T U P & G E N E R A L O P E R A T I O N
D A N G E R
BEFORE STARTING THE
APPLIANCE, MAKE CERTAIN
YOU DO NOT DETECT THE
ODOR OF GAS.
IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open flame.
• Use a telephone OUTSIDE THE
PROPERTY & IMMEDIATELY
contact your gas supplier.
• If unable to contact your gas supplier,
contact the fire department.
OIL
HI
-
LIMIT
RESET
MASTER
POWER
SWITCH
ELEMENT
HI
-
LIMIT
RESET
ELEMENT
HI
-
LIMIT
ALARM
OPEN
CLOSED
KETTLE DRAIN
SELECTOR
A S F - 6 0 G
Содержание FryTech ASF-60G
Страница 65: ...Gas Fryer Operation Care Manual 64 A S F 7 5 G S E R V I C E...
Страница 66: ...Gas Fryer Operation Care Manual 65 A S F 7 5 G S E R V I C E...
Страница 67: ...Gas Fryer Operation Care Manual 66 A S F 7 5 G S E R V I C E...
Страница 68: ...Gas Fryer Operation Care Manual 67 A S F 7 5 G S E R V I C E...