Gas Fryer Operation & Care Manual • 7
I N S T A L L A T I O N
V E N T I L A T I O N
1.
A single ASF-75G or ASF-60G auto-lift gas fryer
requires a minimum of 120 CFM make-up air for
natural gas and 48 CFM for propane gas. Kitchen
ventilation must be of sufficient capacity to prevent a
negative-pressure condition.
DO NOT
obstruct or
restrict ventilation nor the air flow required to support
combustion.
2.
DO NOT
obstruct the flow of the exhaust flue at the
top rear of the fryer. It is especially critical that gas
supply piping and electrical support cord and/or
receptacle be routed away from the path of the hot
combustion fumes.
3.
This fryer cannot be direct vented.
4.
Install the fryer under a ventilation hood meeting all
applicable code requirements. Combustion fumes
must be vented in accordance with local, state, or
national codes.
FAILURE TO VENT THIS FRYER PROPERLY MAY BE
HAZARDOUS TO THE HEALTH OF THE OPERATOR.
Equipment damage and operational problems may
also be the consequence of improper venting. Any
damages sustained by a failure to properly vent this
fryer are not covered under warranty.
Ventilating hoods and exhaust systems shall be
permitted to be used to vent appliances installed in
commercial applications.
Where automatically operated appliances are vented
through a ventilating hood or exhaust system equipped with
a damper or with a power means of exhaust, provisions
shall be made to allow the flow of gas to the main burners
only when the damper is open to a position to properly vent
the appliance and when the power means of exhaust is in
operation.
IN ACCORDANCE WITH
NFPA 54
COMMONWEALTH OF
MASSACHUSETTS ONLY
.
An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing
to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing refer to NFPA No. 96.
D A N G E R
Installation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certified service
technician qualified to work on
gas appliances.
C A U T I O N
To prevent malfunction or cause
negative back draft, DO NOT obstruct
exhaust flues or attach any flue
extension that will impede proper
burner operation.
Содержание FryTech ASF-60G
Страница 65: ...Gas Fryer Operation Care Manual 64 A S F 7 5 G S E R V I C E...
Страница 66: ...Gas Fryer Operation Care Manual 65 A S F 7 5 G S E R V I C E...
Страница 67: ...Gas Fryer Operation Care Manual 66 A S F 7 5 G S E R V I C E...
Страница 68: ...Gas Fryer Operation Care Manual 67 A S F 7 5 G S E R V I C E...
Страница 69: ...Gas Fryer Operation Care Manual 68 A S F 6 0 G S E R V I C E...
Страница 70: ...Gas Fryer Operation Care Manual 69 A S F 6 0 G S E R V I C E...
Страница 71: ...Gas Fryer Operation Care Manual 70 A S F 6 0 G S E R V I C E...
Страница 72: ...Gas Fryer Operation Care Manual 71 A S F 6 0 G S E R V I C E...