CT EXPRESS STEP BY STEP OPERATION
-!.5!,s
54
T R O U B L E S H O O T I N G
ERROR CODES
Error
Code
Error Call Out in Display
Description of Error
Possible Cause
E57
No Rinse Water
During rinse no water
fl ow is detected through
solenoid valve
— Water supply is shut off.
— Low water pressure.
— Check wiring to all components mentioned below.
— Flow switch is dirty or defective.
— Double water solenoid valve defective (Y3.)
— Relay board, high voltage, defective.
E88
Lower Gas Ignition Failure
Ignition system has locked
out due to a failure to create
a consistent fl ame
— Hot Surface Ignitor not functioning.
— No gas supply.
— Flame Sensor not functioning.
E89
Upper Gas Ignition Failure
Ignition system has locked
out due to a failure to create
a consistent fl ame
— Hot Surface Ignitor not functioning.
— No gas supply.
— Flame Sensor not functioning.
E92
Communication Error,
RB Does Not Properly
Respond
Communication error
between display board and
relay board
— Faulty ribbon cable connections between boards.
— Faulty ribbon cable.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E93
Communication Error,
FROM Display Board
Communication error
between display board and
low voltage relay board
— Faulty ribbon cable connections between boards.
— Faulty ribbon cable.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E94
Communication Error,
TO Display Board
Communication error
between display board and
low voltage relay board
— Faulty ribbon cable connections between boards.
— Faulty ribbon cable.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E98
RB is in Celsius and DB is in
Fahrenheit
Change the unit confi guration
in the setup menu
— Control programming issue.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E99
RB is in Fahrenheit and DB
is in Celsius
Change the unit confi guration
in the setup menu
— Control programming issue.
— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E100
DB version is not equal to
RB version. Error generated
by DB.
Software update may have
failed.
— Perform software update.
— Ribbon cable defective.
— Faulty compact fl ash card.
— Relay board, low voltage, connector defective.
— Display board connector defective.
— Software may need to be updated again.
(CONTINUED ON NEXT PAGE)