background image

MT318-101 

DUAL HDMI to HDBT TX

  

User’s Guide

 

400-0749-001 

 

Welcome!

Everyone at Altinex greatly appreciates your purchase of the 
MT318-101. We are confident that you will find it to be reliable 
and simple to use. If you need support, please do not hesitate to 
call us at 714-990-2300.  

At Altinex, we are committed to developing unique and state of 
the art Signal Management Solutions

®

 for demanding audiovisual 

installations. Welcome to the Altinex family of satisfied customers 
around the world! 

1. Precautions and Safety Warnings 

  Please read this manual entirely before using your 

MT318-101. You can download a full version of this 
manual a

www.altinex.com

These instructions are to 

ensure the reliable operation of your switcher and to 
prevent fire and shock hazards. Please read them 
carefully and heed all warnings. 

1.1 General 

  Qualified Altinex service personnel or their authorized 

representatives must perform all service. 

1.2 Installation Precautions 

  To prevent fire or shock, do not expose this unit to water 

or moisture. Do not place the MT318-101 in direct 
sunlight, near heaters or heat-radiating appliances, or near 
any liquid. Exposure to direct sunlight, smoke, or steam 
can harm internal components. 

  Handle carefully; dropping or jarring can cause damage. 

  Do not pull any cables attached to the MT318-101. 

1.3 Cleaning 

  Clean the MT318-101 with a dry cloth only. Never use 

strong detergents or solvents such as alcohol or thinner. 
Do not use a wet cloth or water to clean the card. Do not 
clean or touch any component or PCB. 

1.4 FCC Notice 

  This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) 
this device must accept any interference received, 
including interference that may cause undesired operation. 

  This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to Part 2 of 
the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. 
This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions found herein, may cause 
harmful interference to radio communications. Operation 
of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be 
required to correct the interference at their own expense. 

  Any changes or modifications to the unit not expressly 

approved by Altinex

, Inc. could void the user’s authority to 

operate the equipment. 

 
 
 

2. Installation Procedures

 

Note: 

Download and read the full online manual to become familiar with the MT318-101 and for detailed installation instructions. 

Note: 

For best results, use the MT318-101 power to power the remote stand-alone receiver. 

Do NOT power the stand-alone units with their supplier power adapter. 

Step 1:  Connect to the MultiTasker enclosure using RS232 at 115k baud or a TCP/IP connection; the IP address is visible on the front 

panel LCD. The default IP address is 192.168.10.84 port 23. 

 

Step 2.  The MT318-101 is factory set to 9600 baud and RS232 receive disabled; RS232 transmit is always enabled. 

[TRRSn=dddCii] 

– Send data/enable receive 

[TRTXn=dddCii] 

– Send data/disable receive 

[TRRSn=Cii] 

– Enable receive 

[TRTXn=Cii] 

– Disable receive 

n :  

Port Number (1 or 2) 

ddd :   Serial data (%hh for hex) 

Cii :   Card ID (C1 to C20) 

Step 3.  The MT318-101 is identified by its slot number in the command section in this document. 

Step 4:  Use control commands to configure the RS232 baud rate, send RS232 data from the MT318-101 via the HDBT port to be 

output at the HDBT receiver (UT260-104). 

3. Warranty and Return Policies 

Please visit the Altinex website at 

www.altinex.com

 for details on warranty and return policies. In the case of a unit needing repair, 

please complete an RMA (return material authorization) form by clicking the Warranty link located on the bottom of the Altinex 
homepage. Once completed, please email the form to 

[email protected]

Содержание MT318-101

Страница 1: ...Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses...

Страница 2: ...tput Connectors HDBT Digital Video Audio RJ45 F 2 Table 1 MT318 101 General Mechanical MT318 101 Slots 1 Weight 0 8 lb 0 36 kg actual 0 7 lb Connector Panel Black Anodized T Operating 10 C 45 C Humidi...

Страница 3: ...d a valid command Invalid commands generate feedback that includes ER and may also include an error code ERC04 Card C4 slot 4 failed to execute a command Check command syntax Check values sent are wit...

Страница 4: ...3011C04 Power in milliwatts 03011 3 011 mW Card power 5 digits End status 4 S SAVE This command saves the configuration command being sent in memory Send I1O1C8S and after reset or power up Input 1 is...

Страница 5: ...PWRCii Example Read the power consumption of the card in slot 4 by sending PWRC4 feedback is like the following 4 59WC04 12 PWRM Same as the PWR command but returns milliwatts Command Format PWRMCii E...

Страница 6: ...ort Use this command when data from the device is expected by the control application This command may be used with the S option to set the startup state of the receive option Command Format TRRSn dd...

Страница 7: ...m the controller the application can be used to respond to data received from the projector for example TEMP1 indicating its internal temperature is too high RS1TEMP1C04 Data may be returned in any of...