MT318-101
User’s Guide
400-0742-001
5
8.
[HWEN]
This command enables or disables the card hardware,
excluding the main microprocessor. Power to video and
audio circuitry is turned off. Use for saving power but to
keep response time short returning to normal operation.
Either HDBT receiver can be disabled individually or as a
pair. This is not a group command.
Show the status of the hardware enable.
Command Format: [HWENCii]
Returns [x]
x
= 0
Rx1 and Rx2 are off
= 1
Rx1 and Rx2 are on
= 2
Rx1 on, Rx2 off
= 3
Rx1 off, Rx2 on
Command Format: [HWENxCii]
x
= On/off (1 = on, 0 = off)
Command Format: [HWENxnCii]
x
= On/off (1 = on, 0 = off)
n
= HDBT Rx (1 or 2)
Example:
Disable the hardware to the HDBT Rx card in slot 4 by
sending the following command:
[HWEN0C4]
9.
[MOD]
This command returns the card model number.
Command Format: [MODCii]
Example:
Read the model of the card in slot 4 by sending [MODC4];
feedback is like the following:
[MT318-101C04]
10. [PRG]
This command puts the card into firmware update mode.
Only use when working with Altinex Technical Support.
Command Format: [PRGCii]
11. [PWR]
This command returns the card power consumption in
watts.
Command Format: [PWRCii]
Example:
Read the power consumption of the card in slot 4 by
sending [PWRC4]; feedback is like the following:
[4.59WC04]
12. [PWRM]
Same as the [PWR] command but returns milliwatts.
Command Format: [PWRMCii]
Example:
Read the power consumption (in milliwatts) of the card in
slot 4 by sending [PWRMC4]; feedback is like the following:
[4596mWC04]
13. [SFT]
This command resets the card. It is the equivalent to
powering just the card off and on.
Command Format: [SFTCii]
Example:
Reset the card in slot by sending [SFTC4]. The card
responds with [RSTC04] indicating the card is resetting.
14. [STA]
This command enables and disables automatic feedback
from the card. The feedback format is the same as the [?Ci]
command, but only changes are reported.
Command Format: [STAxCii]
x
= On/off (x = 1 to enable, 0 disables)
Feedback Prefix Definitions:
MT Card Model Number
RI
RS232 Settings
VR Firmware Revision
PR Card power consumption
TP Card Temperature
15. [TEMP]
Read card temperature in degrees Celsius.
Command Format: [TEMPCii]
Example:
Send [TEMPC4] to read the temperature of slot 4
’s card.
[39C04]
16. [VER]
This command displays the software version and card type
for the card.
Command Format: [VERCii]
Example:
Send the command [VERC4] to check the version of the
MT318-101 in slot 4. The card returns feedback:
[690-0465-001C04]
690-0465-001 = firmware version
C04 = card ID