MT318-101
User’s Guide
400-0742-001
7
20. (RS)
This is unsolicited feedback. The RS232 data received by
the MT318-101 from the Rx is sent to the MultiTasker
control when received on either port. The data is not
analyzed; it is simply relayed to the MultiTasker, in one or
more groups depending on how the data is received.
Data from the MultiTasker may be accessed from either the
TCP or RS232 port. The
MultiTasker’s RS232 output is
115k baud, regardless of the MT318-101 baud rate.
Important: Make sure to configure the RS232 ports to
match the baud rate of the equipment connected to each
port. See the [MODERS] command for details.
Feedback Format:
(RSndddCii)
n
= RS-232 port number (n=1 or 2)
ddd = Data received through RS-232 port
Example:
The MT318-101 port 1 is connected to an HDBT Rx. In
addition to controlling the projector from the controller, the
application can be used to respond to data received from
the projector; for example, "TEMP1" indicating its internal
temperature is too high.
(RS1TEMP1C04)
Data may be returned in any of the 3 examples below and
depends on how the data is received and string length:
1. (RS1
TEMP1
C04)
2. (RS1
TE
C04)(RS1
MP
C04)(RS1
1
C04)
3. (RS1
T
C04)(RS1
E
C04)(RS1
MP
C04)(RS1
1
C04)
5.6 Summary of Commands
Common Commands
1. [C]
Card status
2. [CiS]
Save all settings
3. [?C]
Parseable card status
4.
[…S]
Save single command
5. [DISP]
Return card information
6. [FRST]
Factory reset
7. [GROUP]
Set or read group number
8. [HWEN]
Hardware enable/disable
9. [MOD]
Return card model
10. [PRG]
Firmware update mode
11. [PWR]
Return card power in watts
12. [PWRM]
Return card power in milliwatts
13. [SFT]
Reset the card
14. [STA]
Enable/disable unsolicited feedback
15. [TEMP]
Return card temperature
16. [VER]
Return firmware version
RS232 Commands
17. [MODERS]
Configure RS232 ports
18. [TRRS]
Output RS232 data
19. [TRTX]
Output RS232 data, disable RX
20. (RS)
Unsolicited data received on RS232
ports