background image

MT318-101 

User’s Guide

 

400-0742-001 

 

 
 
 
 
 
 

 

RS232 Commands 

The RS232 pass-through feature is available with different 
baud rates. It is important to make sure that both the 
transmitter and receiver are set for the same baud rate.  

Not all characters are supported. Following is a list of the valid 
RS232 character range: 

 

0x00 

0x08 

Not valid 

 

0x09 

0x7E 

Valid 

17.  [MODERS] 

Configure the RS-232 port for baud rate. Once configured, 
data sent to or received on a given port is in the set format. 
This command applies to both ports. 

Command Format: 

[MODERSnbpdsCii] 

[MODERSCii] 

RS-232 port number (1 or 2) 

Both ports share the same baud rate. Setting one port 
sets both ports. 

baud rate (1 ~ 8) 

1 = 1200 bps 

2 = 2400 bps 

3 = 4800 bps 

4 = 9600 bps ....... (compatible with UT260-104) 

5 = 19200 bps ..... (compatible with UT260-104) 

6 = 38400 bps ..... (compatible with UT260-104) 

7 = 57600 bps 

8 = 115200 bps ... (compatible with UT260-104*) 

* UT260-103 default baud rate. 

parity for 8-bit/1 stop bit data only 
0=none (parity is fixed) 

data bits 
0=8 bits (data bits are fixed) 

stop bits 
1=1 stop bit (stop bits are fixed) 

 
Example: 

Set the RS232 port #1 to 19200 baud by sending: 

     [MODERS15001C04] 

Once complete, the confirmation is returned by the card. 

     [C04] 

Send [MODERSC04] command with no options to receive 
the current settings. 

     [19200,N,8,1C04]   

18.  [TRRS] 

Send a string of data through one of the HDBT Tx ports 
and enable the receive option on the same port. The data 
sent using this command is output on the RS232 port of the 
Rx (UT260-104) connected via the HDBT port. 

Use this command when data from the device is expected 
by the control application. This command may be used with 
the [..S] option to set the startup state of the receive option. 

Command Format: 

[TRRSn=dd

…dCii] 

[TRRSn=dd…dCiiS] Send & save 

=  Port number (1 or 2) 

ddd  =  data to be transmitted (keyboard characters) 

Use % for HEX value (ex: %0D=carriage return) 

 

 

Send no data to simply enable the Rx port. For 
example, send [TRRS1=C04] to enable the 
receive option on the card port. 

Example: 

Output “[VER]” on the RS-232 port of the Rx 
connected to HDBT port #1 by sending the 
following to the controller:  

 

[TRRS1=%5BVER%5DC04]  

Feedback from the Rx is received by the 
MultiTasker in the form of (RSndd…dC04). See 
the (RS) command for details. 

19.  [TRTX] 

Send a string of data through one of the RS232 ports and 
disable the receive option on the same port. The data sent 
using this command is output on the RS232 port of the Rx 
(UT260-104) connected via the HDBT port. 

Optimize system performance using this command when 
data from the device is not used by the control application. 

Excess data from external devices uses card processor 
time as well as enclosure bus resources. In severe cases, 
overall MultiTasker performance may be affected. 

Command Format: 

[TRTXn=dddCii] 
[TRTXn=dd…dCiiS] Send & save 

=  Port number (1 or 2) 

ddd  =  data to be transmitted (keyboard characters) 

Use % for HEX value (ex: %0D=carriage return) 

 

 

Send no data to simply disable the Rx port. For 
example, send [TRTX1=C04] to disable the 
receive option on a card port. 

Example: 

Output “[VER]” on RS-232 port #1 by sending the 
following to the controller: 

 

[TRRS1=%5BVER%5DC04]  

Feedback from the Rx is received by the 
MultiTasker in the form of (RSndd…dC04). See 
the (RS) command for details. 

Содержание MT318-101

Страница 1: ...Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses...

Страница 2: ...tput Connectors HDBT Digital Video Audio RJ45 F 2 Table 1 MT318 101 General Mechanical MT318 101 Slots 1 Weight 0 8 lb 0 36 kg actual 0 7 lb Connector Panel Black Anodized T Operating 10 C 45 C Humidi...

Страница 3: ...d a valid command Invalid commands generate feedback that includes ER and may also include an error code ERC04 Card C4 slot 4 failed to execute a command Check command syntax Check values sent are wit...

Страница 4: ...3011C04 Power in milliwatts 03011 3 011 mW Card power 5 digits End status 4 S SAVE This command saves the configuration command being sent in memory Send I1O1C8S and after reset or power up Input 1 is...

Страница 5: ...PWRCii Example Read the power consumption of the card in slot 4 by sending PWRC4 feedback is like the following 4 59WC04 12 PWRM Same as the PWR command but returns milliwatts Command Format PWRMCii E...

Страница 6: ...ort Use this command when data from the device is expected by the control application This command may be used with the S option to set the startup state of the receive option Command Format TRRSn dd...

Страница 7: ...m the controller the application can be used to respond to data received from the projector for example TEMP1 indicating its internal temperature is too high RS1TEMP1C04 Data may be returned in any of...

Отзывы: