background image

MT318-101 

User’s Guide

 

400-0742-001 

 

 

 

 
 
 
 
 
 

 

4. Technical Specifications 

Specifications are subject to change. See 

www.altinex.com

 for up-to-date information. 

 

Features/Description 

MT318-101 

General 

 

Input Connectors 

 

Digital Video + Audio 

HDMI F, Type A (2) 

Output Connectors 

 

HDBT Digital Video + Audio 

RJ45 F (2) 

Table 1. MT318-101 General 

 

Mechanical 

MT318-101 

Slots 

Weight 

0.8 lb. (0.36 kg) 

 

actual 0.7 lb.

 

Connector Panel 

Black Anodized 

T° Operating 

10°C-45°C 

Humidity 

90% non-condensing 

MTBF (calc.) 

38,000 hrs. 

Table 2. MT318-101 Mechanical 

Electrical 

MT318-101 

Inputs 

 

Digital Video + Audio 

HDMI Standard 

Outputs 

 

Digital Video + Audio 

HDbaseT

 

Power Consumption 

 

+12V Bus Power 

1.5 A (18W) max. 

Table 3. MT318-101 Electrical 
 

 

Содержание MT318-101

Страница 1: ...Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses...

Страница 2: ...tput Connectors HDBT Digital Video Audio RJ45 F 2 Table 1 MT318 101 General Mechanical MT318 101 Slots 1 Weight 0 8 lb 0 36 kg actual 0 7 lb Connector Panel Black Anodized T Operating 10 C 45 C Humidi...

Страница 3: ...d a valid command Invalid commands generate feedback that includes ER and may also include an error code ERC04 Card C4 slot 4 failed to execute a command Check command syntax Check values sent are wit...

Страница 4: ...3011C04 Power in milliwatts 03011 3 011 mW Card power 5 digits End status 4 S SAVE This command saves the configuration command being sent in memory Send I1O1C8S and after reset or power up Input 1 is...

Страница 5: ...PWRCii Example Read the power consumption of the card in slot 4 by sending PWRC4 feedback is like the following 4 59WC04 12 PWRM Same as the PWR command but returns milliwatts Command Format PWRMCii E...

Страница 6: ...ort Use this command when data from the device is expected by the control application This command may be used with the S option to set the startup state of the receive option Command Format TRRSn dd...

Страница 7: ...m the controller the application can be used to respond to data received from the projector for example TEMP1 indicating its internal temperature is too high RS1TEMP1C04 Data may be returned in any of...