MULTITASKER™
400-0367-004
11
Example 2: [MAT1;16;16;00;00;02;00;C5S]
Inputs = 16
Outputs = 16
Input Offset = 00
Output Offset = 00
Width = 02
Spacing = 00
In this configuration, if Input 1 is connected to
Output 16, the entire channel, 1a and 1b, will be
switched to outputs 16a and 16b respectively.
Input Cards
Output Cards
4
3
2
1
1
2
3
4
13a
9a
5a
1a
1a
5a
9a
13a
13b
9b
5b
1b
1b
5b
9b
13b
14a 10a
6a
2a
2a
6a
10a 14a
14b 10b
6b
2b
2b
6b
10b 14b
15a 11a
7a
3a
3a
7a
11a 15a
15b 11b
7b
3b
3b
7b
11b 15b
16a 12a
8a
4a
4a
8a
12a 16a
16b 12b
8b
4b
4b
8b
12b 16b
6.
[M
j
C
n
]
This command selects the matrix to be active.
Command Format: [MjCnUi]
j
= Matrix ID (j = # from 1 to 9)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is a matrix engine in slot 5. Send the
command [M1C5] to recall matrix
configuration #1 of card 5.
RECALL MATRIX ON POWER UP
In order to make configuration #1 of card 5 the
default configuration when power is turned on,
send the [M1C5S]. The feedback will be:
[SAVEDC05]
7.
[ONmmCn]
This command turns on a single output for the
current matrix.
Command Format: [ONmmCnUi]
mm = Output Number (mm = # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is an
MT107-103
in slot 5. Turn ON
output number 64 by sending the command
[ON64C5].
8.
[ONCn]
This command turns on all outputs for the
current matrix.
Command Format: [ONCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is an
MT107-103
in slot 5. Turn ON ALL
outputs by sending the command [ONC5].
9.
[OFFmmCn]
This command turns off a single output for the
current matrix.
Command Format: [OFFmmCnUi]
mm = Output Number (mm = # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is an
MT107-103
in slot 5. Turn OFF only
output number 01 by sending the command
[OFF01C5].
10.
[OFFCn]
This command turns off all outputs for the
current matrix.